Motor Protection Circuit-Breaker (140M-F8E-C25)
MFG #140M-F8E-C25
$702.70 / E
EACH
EACH
Product Description:
MPCB, Standard Magnetic Trip (Fixed at 13 x le), 18 - 25 A, High Performance, Frame Size F
HESCO Part Number
AB140MF8EC25
UPC
662468964517
Manufacturer Part Number
140M-F8E-C25
Manufacturer
Allen-Bradley
Motor Protection Circuit-Breaker (140M-F8E-C25)
MFG #140M-F8E-C25
Product Description:
MPCB, Standard Magnetic Trip (Fixed at 13 x le), 18 - 25 A, High Performance, Frame Size F
HESCO Part Number
AB140MF8EC25
UPC
662468964517
Manufacturer Part Number
140M-F8E-C25
Manufacturer
Allen-Bradley
$702.70 / E
EACH
EACH
- Features
- Specifications
- Resources
- China CCC
- Mtr Prt Circuit Breaker application
- -25 °C ambient operating temperature
- -40 °C ambient storage temperature
- -25 °C ambient temperature compensation
- High breaking capacity
- Operating humidity/moisture heat (60068-2-3): 5.95% non-condensing
- 100-C30, UL-508 -Type E self-protected combination motor controller
- 18.25 A
General Features
| Application | : | Mtr Prt Circuit Breaker |
Power Electrical Characteristics | ||
| Current range | : | 18.25 A |
| Electrical life cycle | : | 30000 ops (Ie maximum) |
| Hp rating, max | : | 7.5kA @ 230V, 3-phase |
| KW rating, max | : | 22 kW @ 690V (AC-3), 3-phase |
| Magnetic trip current, nom | : | 325 A |
| Number of poles | : | 3 |
| Phase failure sensitive | : | true |
| Phase loss protection | : | Differential release |
| Rated frequency | : | 45 Hz |
| Rated operating voltage | : | 230 A |
| Rated permanent current Iu | : | 25 A |
| Switching frequency, max | : | 25 ops/h |
| Switch off technique | : | Thermomagnetic |
| Trip class | : | 10 |
| Type of control element | : | Turn button |
| With thermal protection | : | true |
Construction | ||
| Contactor size, min | : | 100-C30, UL-508 -Type E self-protected combination motor controller |
| Device construction | : | Built-in device fixed built-in technique |
| Frame size | : | Frame size F, 45 A |
Mechanical | ||
| Breaking capacity | : | High breaking capacity |
| Factory option | : | No circuit-breaker auxiliary or trip contacts |
| Mechanical life operations | : | 30000 /h |
| Protection type | : | Adjustable thermal/fixed magnetic (13 x In) |
| Shock | : | Transport (60068-2-27): 30 G/11 ms, OFF |
| Vibration | : | ops (60068-2-6): 5 G |
| Weight | : | 782 lb |
Standards Protection | ||
| Ambient operating temperature | : | -25 °C |
| Ambient storage temperature | : | -40 °C |
| Ambient temperature compensation | : | -25 °C |
| Climatic resistance | : | Operating humidity/moisture heat (60068-2-3): 5.95% non-condensing |
| Dependence on temperature | : | No reduction @ 60 °C (140 °F) |
| Pollution degree | : | 3 |
| Site altitude | : | to 2000 m N.N. (6561 ft) |
Overview | ||
| Standard Warranty Duration | : | 1 year |
Specifications | ||
| Build America, Buy America | : | No |
| Repair Options Available | : | No |
| Degree of protection | : | IP2X |
| Depth | : | 110 mm |
| Height | : | 111.4 mm |
| Insulation voltage | : | Rated 690V per IEC |
| Magnetic release current | : | Fixed setting: 18…22 x Ie maximum (Ie maximum = maximum values of setting ranges) for T version |
| Rated supply current | : | 6.3 A |
| Rated thermal current | : | 6.3.45 A up to 60 °C (140 °F) ambient temperature |
| Width | : | 54 mm |
| Country of Origin | : | Switzerland |
- China CCC
- Mtr Prt Circuit Breaker application
- -25 °C ambient operating temperature
- -40 °C ambient storage temperature
- -25 °C ambient temperature compensation
- High breaking capacity
- Operating humidity/moisture heat (60068-2-3): 5.95% non-condensing
- 100-C30, UL-508 -Type E self-protected combination motor controller
- 18.25 A
General Features
Application : Mtr Prt Circuit Breaker Power Electrical Characteristics
Current range : 18.25 A Electrical life cycle : 30000 ops (Ie maximum) Hp rating, max : 7.5kA @ 230V, 3-phase KW rating, max : 22 kW @ 690V (AC-3), 3-phase Magnetic trip current, nom : 325 A Number of poles : 3 Phase failure sensitive : true Phase loss protection : Differential release Rated frequency : 45 Hz Rated operating voltage : 230 A Rated permanent current Iu : 25 A Switching frequency, max : 25 ops/h Switch off technique : Thermomagnetic Trip class : 10 Type of control element : Turn button With thermal protection : true Construction
Contactor size, min : 100-C30, UL-508 -Type E self-protected combination motor controller Device construction : Built-in device fixed built-in technique Frame size : Frame size F, 45 A Mechanical
Breaking capacity : High breaking capacity Factory option : No circuit-breaker auxiliary or trip contacts Mechanical life operations : 30000 /h Protection type : Adjustable thermal/fixed magnetic (13 x In) Shock : Transport (60068-2-27): 30 G/11 ms, OFF Vibration : ops (60068-2-6): 5 G Weight : 782 lb Standards Protection
Ambient operating temperature : -25 °C Ambient storage temperature : -40 °C Ambient temperature compensation : -25 °C Climatic resistance : Operating humidity/moisture heat (60068-2-3): 5.95% non-condensing Dependence on temperature : No reduction @ 60 °C (140 °F) Pollution degree : 3 Site altitude : to 2000 m N.N. (6561 ft) Overview
Standard Warranty Duration : 1 year Specifications
Build America, Buy America : No Repair Options Available : No Degree of protection : IP2X Depth : 110 mm Height : 111.4 mm Insulation voltage : Rated 690V per IEC Magnetic release current : Fixed setting: 18…22 x Ie maximum (Ie maximum = maximum values of setting ranges) for T version Rated supply current : 6.3 A Rated thermal current : 6.3.45 A up to 60 °C (140 °F) ambient temperature Width : 54 mm Country of Origin : Switzerland - Downloads
Spec Sheet