Allen-Bradley
Expansion 4-20mA Output Module
MFG #1444-AOFX00-04RB
$2,424.61 / E
EACH
EACH
Product Description:
4-20mA Expansion Module
HESCO Part Number
AB1444AOFX0004RB
UPC
885630427089
Manufacturer Part Number
1444-AOFX00-04RB
Manufacturer
Allen-Bradley
Allen-Bradley
Expansion 4-20mA Output Module
MFG #1444-AOFX00-04RB
Product Description:
4-20mA Expansion Module
HESCO Part Number
AB1444AOFX0004RB
UPC
885630427089
Manufacturer Part Number
1444-AOFX00-04RB
Manufacturer
Allen-Bradley
$2,424.61 / E
EACH
EACH
- Features
- Specifications
- Resources
- 4 number of outlet
- China CCC
- 1% @ full scale accuracy
- IECEx Scheme
- A digital network that is used between a main module and its expansion modules is implemented on the local bus, Communication does not link main modules
- ATEX
- 1 s communication time-out, fixed
- 10V rms with 1 kHz sine-wave 80% AM from 150 kHz.80 MHz
- 85 °C conductor/insulation temperature rating
General Features
| Number Of Outlet | : | 4 |
| Number of status indicators | : | 6 |
| Status indicator | : | Power channel status (4), Local bus status |
Inputs Outputs Io | ||
| Current output, max | : | 20 mA per output channel |
| Not OK output | : | Configurable: force low (2.9 mA), force high (>20 mA), hold current level |
| Number of channels | : | 4 |
| Protection | : | Insensitive to polarity |
Power Electrical Characteristics | ||
| Accuracy | : | 1% @ full scale |
| Analogue inputs configurable | : | false |
| Analogue outputs configurable | : | false |
| Communication time-out, fixed | : | 1 s |
| Conductor type | : | Copper |
| Consumption | : | 0.76 W |
| Current | : | 18mA @ 24V (22.8mA @ 18.32V) |
| Dissipation | : | 3.6 W |
| Input, current | : | false |
| Input, resistance thermometer | : | false |
| Input, resistor | : | false |
| Input signal, configurable | : | false |
| Input, thermocouple | : | false |
| Input, voltage | : | false |
| Isolation voltage | : | 50V (continuous), basic insulation type between signal ports and AUX bus, No isolation between individual signal ports, Type tested at 707V DC @ 60s |
| Number of analogue outputs | : | 4 |
| Output, current | : | true |
| Output signal configurable | : | true |
| Output, voltage | : | false |
| Type of electric connection | : | Screw-/spring clA connection |
| Voltage | : | North American: 18.32V, max 8 A, limited voltage source |
| Wire type | : | Shielded on all signal ports |
| Wiring category | : | 2 - on signal ports |
Communication Interfaces | ||
| Communication | : | A digital network that is used between a main module and its expansion modules is implemented on the local bus, Communication does not link main modules |
| TTL signals | : | Dual independent TTL signals, with tachom sensor status, are passed on the Local Bus, There can be only one tachom expansion module on a local bus, The TTL signal can serve up to six main modules |
Construction | ||
| Depth | : | With terminal base: 158 mm |
| Enclosure type rating | : | None (open-style) |
| Height | : | With terminal base: 96 mm |
| Width | : | With terminal base: 54 mm |
Mechanical | ||
| Shock | : | Operating: 15 G |
| Stripping length | : | 9 mm |
| Vibration | : | 2.0 G @ 10…500 Hz |
| Weight | : | Without terminal base: 0.14 kg |
Alarms Fault Management | ||
| Indication | : | Update module status indicator |
Standards Protection | ||
| Conducted RF immunity | : | 10V rms with 1 kHz sine-wave 80% AM from 150 kHz.80 MHz |
| Conductor/insulation temperature rating | : | 85 °C |
| Conformal coating | : | All printed circuit boards are conformal coated in accordance with IPC-A-610C and in compliance with: IPC-CC-830 B, UL508 |
| EFT/B immunity | : | ±2kV @ 5kHz on shielded signal ports |
| Emissions | : | IEC 61000-6-4 |
| ESD immunity | : | 6 kV contact discharges, 8 kV air discharges |
| Nonoperating temperature | : | -40 °C |
| Operating temperature | : | -25 °C |
| Radiated RF immunity | : | 10 V/m with 1 kHz sine-wave 80% AM from 80.2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 1 V/m with 1 kHz sine-wave 80% AM from 2000.2700 MHz |
| Relative humidity | : | 5.95% noncondensing |
| Surge transient immunity | : | ±2 kV line-earth (CM) on shielded signal ports |
Overview | ||
| Standard Warranty Duration | : | 1 year |
Specifications | ||
| Build America, Buy America | : | No |
| Repair Options Available | : | No |
| Conductor UL/cUL AWG | : | 0.05 mm² |
| Torque | : | 0.22 nm |
| Country of Origin | : | United States |
- 4 number of outlet
- China CCC
- 1% @ full scale accuracy
- IECEx Scheme
- A digital network that is used between a main module and its expansion modules is implemented on the local bus, Communication does not link main modules
- ATEX
- 1 s communication time-out, fixed
- 10V rms with 1 kHz sine-wave 80% AM from 150 kHz.80 MHz
- 85 °C conductor/insulation temperature rating
General Features
Number Of Outlet : 4 Number of status indicators : 6 Status indicator : Power channel status (4), Local bus status Inputs Outputs Io
Current output, max : 20 mA per output channel Not OK output : Configurable: force low (2.9 mA), force high (>20 mA), hold current level Number of channels : 4 Protection : Insensitive to polarity Power Electrical Characteristics
Accuracy : 1% @ full scale Analogue inputs configurable : false Analogue outputs configurable : false Communication time-out, fixed : 1 s Conductor type : Copper Consumption : 0.76 W Current : 18mA @ 24V (22.8mA @ 18.32V) Dissipation : 3.6 W Input, current : false Input, resistance thermometer : false Input, resistor : false Input signal, configurable : false Input, thermocouple : false Input, voltage : false Isolation voltage : 50V (continuous), basic insulation type between signal ports and AUX bus, No isolation between individual signal ports, Type tested at 707V DC @ 60s Number of analogue outputs : 4 Output, current : true Output signal configurable : true Output, voltage : false Type of electric connection : Screw-/spring clA connection Voltage : North American: 18.32V, max 8 A, limited voltage source Wire type : Shielded on all signal ports Wiring category : 2 - on signal ports Communication Interfaces
Communication : A digital network that is used between a main module and its expansion modules is implemented on the local bus, Communication does not link main modules TTL signals : Dual independent TTL signals, with tachom sensor status, are passed on the Local Bus, There can be only one tachom expansion module on a local bus, The TTL signal can serve up to six main modules Construction
Depth : With terminal base: 158 mm Enclosure type rating : None (open-style) Height : With terminal base: 96 mm Width : With terminal base: 54 mm Mechanical
Shock : Operating: 15 G Stripping length : 9 mm Vibration : 2.0 G @ 10…500 Hz Weight : Without terminal base: 0.14 kg Alarms Fault Management
Indication : Update module status indicator Standards Protection
Conducted RF immunity : 10V rms with 1 kHz sine-wave 80% AM from 150 kHz.80 MHz Conductor/insulation temperature rating : 85 °C Conformal coating : All printed circuit boards are conformal coated in accordance with IPC-A-610C and in compliance with: IPC-CC-830 B, UL508 EFT/B immunity : ±2kV @ 5kHz on shielded signal ports Emissions : IEC 61000-6-4 ESD immunity : 6 kV contact discharges, 8 kV air discharges Nonoperating temperature : -40 °C Operating temperature : -25 °C Radiated RF immunity : 10 V/m with 1 kHz sine-wave 80% AM from 80.2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 1 V/m with 1 kHz sine-wave 80% AM from 2000.2700 MHz Relative humidity : 5.95% noncondensing Surge transient immunity : ±2 kV line-earth (CM) on shielded signal ports Overview
Standard Warranty Duration : 1 year Specifications
Build America, Buy America : No Repair Options Available : No Conductor UL/cUL AWG : 0.05 mm² Torque : 0.22 nm Country of Origin : United States - Downloads
Spec Sheet