IEC 12 A Miniature Contactor (100-K12KA10)
MFG #100-K12KA10
$162.56 / E
EACH
EACH
Product Description:
Miniature Contactor, Screw Type Terminals, 12A, System Control Voltage: 240V 50/60Hz, 3 N.O. Main Contacts, 1 N.O. Auxiliary Contact, 1
HESCO Part Number
AB100K12KA10
UPC
662074492275
Manufacturer Part Number
100-K12KA10
Manufacturer
Allen-Bradley
IEC 12 A Miniature Contactor (100-K12KA10)
MFG #100-K12KA10
Product Description:
Miniature Contactor, Screw Type Terminals, 12A, System Control Voltage: 240V 50/60Hz, 3 N.O. Main Contacts, 1 N.O. Auxiliary Contact, 1
HESCO Part Number
AB100K12KA10
UPC
662074492275
Manufacturer Part Number
100-K12KA10
Manufacturer
Allen-Bradley
$162.56 / E
EACH
EACH
- Features
- Specifications
- Resources
- 1 N.O.,3 N.O. Poles
- 12 A contactor size
- Screw Type Terminals special features
- 2000 m (NN) per IEC 60947-4 altitude, max
- Storage: -55.80 (-67.176)
- 1 NO auxiliary contact configuration
- IP2X auxiliary contacts
- 750 µF @ short-circuit current of 10 kA
General Features
| Contact Configuration | : | 1 N.O.,3 N.O. Poles |
| Contactor Size | : | 12 A |
| Special Features | : | Screw Type Terminals |
Power Electrical Characteristics | ||
| Auxiliary contact configuration | : | 1 NO |
| Auxiliary contacts | : | IP2X |
| Capacitance, max | : | 750 µF @ short-circuit current of 10 kA |
| Coil consumption, hold-in | : | Cold 3.0 W, warm 2.6 W DC (conventional) |
| Coil consumption, pick-up | : | Cold 3.0 W, warm 2.6 W DC (conventional) |
| Insulation class of the coil | : | Class F per IEC 60085, Class 105 insulation system per UL 508 |
| Operating limits, dropout | : | (0.2.0.75) x Us @ 50 Hz, 60 Hz, 50/60 Hz |
| Operating limits, pick-up | : | (0.85.1.1) x Us @ 50 Hz, 60 Hz, 50/60 Hz |
| Operating time, closing delay | : | 6.12 ms DC (conventional) |
| Operating time, opening delay | : | 8.12 ms with integrated diode |
| Optional accessories | : | Front-mount auxiliary contacts, surge suppressors, electronic timers, mechanical interlocks |
| Optional overload relays | : | Bimetallic |
| Rated filament current | : | 9A @ 230/240V, AC-5b |
| Rating for switching AC motors | : | 3-poles: 7.5Hp @ 575V (AC-2, AC-3, AC-4), 3-phase (60 Hz) |
| Switching of DC loads | : | 3-poles in series: 9A @ 48/60V (Non-inductive or slightly inductive loads or resistance furnaces DC-1 at 60 °C) |
| Switching of lamps | : | Gas discharge lA, open: 18A @ 40°C, AC-5a |
| Switching of motor load | : | 11A @ 400V, AC-7b (50 Hz) |
| Total power dissipation | : | DC control: 3.5 W @ 400V, AC-3, Ie |
| Voltage type for actuating | : | AC |
Mechanical | ||
| Altitude, max | : | 2000 m (NN) per IEC 60947-4 |
| Conductor cross section | : | Main contact, 2 conductor: 1.2.5 mm² + 1.4 mm² |
| Lifespan | : | Mechanical DC control: 15000000 ops |
| Recommended torque | : | 10.6 in-lb |
| Shock resistance | : | IEC 60068-2 |
| Vibration resistance | : | IEC 60068-2 |
| Weight | : | DC: 0.2 kg |
Standards Protection | ||
| Ambient temperature | : | Storage: -55.80 (-67.176) |
| Climatic withstand | : | IEC 60068-2-30 |
Overview | ||
| Standard Warranty Duration | : | 1 year |
Specifications | ||
| Build America, Buy America | : | No |
| Repair Options Available | : | No |
| General purpose current | : | 18 A per UL/CSA |
| Power dissipation | : | 0.9 W @ 400V, AC-3, Ie |
| Rated current | : | 9.6A @ 230V, 3-phase per UL/CSA |
| Rated isolation voltage | : | IEC: 690V, UL, CSA: 600V |
| Rated operational current | : | 9.2A @ 500V, AC-4 (50 Hz), ambient temperature 60 °C |
| Rated operational power | : | 8.3 kW @ 240V, AC-1 (50 Hz), ambient temperature 40 °C |
| Rated power | : | 7.5Hp @ 575V, 3-phase per UL/CSA |
| Short time withstand | : | 96A @ 10s, 60 °C |
| Switching frequency, max | : | 250 ops/h, AC-4 |
| Country of Origin | : | Switzerland |
- 1 N.O.,3 N.O. Poles
- 12 A contactor size
- Screw Type Terminals special features
- 2000 m (NN) per IEC 60947-4 altitude, max
- Storage: -55.80 (-67.176)
- 1 NO auxiliary contact configuration
- IP2X auxiliary contacts
- 750 µF @ short-circuit current of 10 kA
General Features
Contact Configuration : 1 N.O.,3 N.O. Poles Contactor Size : 12 A Special Features : Screw Type Terminals Power Electrical Characteristics
Auxiliary contact configuration : 1 NO Auxiliary contacts : IP2X Capacitance, max : 750 µF @ short-circuit current of 10 kA Coil consumption, hold-in : Cold 3.0 W, warm 2.6 W DC (conventional) Coil consumption, pick-up : Cold 3.0 W, warm 2.6 W DC (conventional) Insulation class of the coil : Class F per IEC 60085, Class 105 insulation system per UL 508 Operating limits, dropout : (0.2.0.75) x Us @ 50 Hz, 60 Hz, 50/60 Hz Operating limits, pick-up : (0.85.1.1) x Us @ 50 Hz, 60 Hz, 50/60 Hz Operating time, closing delay : 6.12 ms DC (conventional) Operating time, opening delay : 8.12 ms with integrated diode Optional accessories : Front-mount auxiliary contacts, surge suppressors, electronic timers, mechanical interlocks Optional overload relays : Bimetallic Rated filament current : 9A @ 230/240V, AC-5b Rating for switching AC motors : 3-poles: 7.5Hp @ 575V (AC-2, AC-3, AC-4), 3-phase (60 Hz) Switching of DC loads : 3-poles in series: 9A @ 48/60V (Non-inductive or slightly inductive loads or resistance furnaces DC-1 at 60 °C) Switching of lamps : Gas discharge lA, open: 18A @ 40°C, AC-5a Switching of motor load : 11A @ 400V, AC-7b (50 Hz) Total power dissipation : DC control: 3.5 W @ 400V, AC-3, Ie Voltage type for actuating : AC Mechanical
Altitude, max : 2000 m (NN) per IEC 60947-4 Conductor cross section : Main contact, 2 conductor: 1.2.5 mm² + 1.4 mm² Lifespan : Mechanical DC control: 15000000 ops Recommended torque : 10.6 in-lb Shock resistance : IEC 60068-2 Vibration resistance : IEC 60068-2 Weight : DC: 0.2 kg Standards Protection
Ambient temperature : Storage: -55.80 (-67.176) Climatic withstand : IEC 60068-2-30 Overview
Standard Warranty Duration : 1 year Specifications
Build America, Buy America : No Repair Options Available : No General purpose current : 18 A per UL/CSA Power dissipation : 0.9 W @ 400V, AC-3, Ie Rated current : 9.6A @ 230V, 3-phase per UL/CSA Rated isolation voltage : IEC: 690V, UL, CSA: 600V Rated operational current : 9.2A @ 500V, AC-4 (50 Hz), ambient temperature 60 °C Rated operational power : 8.3 kW @ 240V, AC-1 (50 Hz), ambient temperature 40 °C Rated power : 7.5Hp @ 575V, 3-phase per UL/CSA Short time withstand : 96A @ 10s, 60 °C Switching frequency, max : 250 ops/h, AC-4 Country of Origin : Switzerland - Downloads
Spec Sheet
General