
IEC Miniature Reversing Contactor (104-K12D02)
MFG #104-K12D02
$414.27 / E
EACH
EACH
Product Description:
104-K Mini Reversing Contactors, Screw Type Terminals, 12A, System Control Voltage: 110V 50Hz/120V 60Hz, 3 N.O. Main Contacts, 1 N.C. Auxiliary Contact
HESCO Part Number
AB104K12D02
UPC
662074500611
Manufacturer Part Number
104-K12D02
Manufacturer
Allen-Bradley
IEC Miniature Reversing Contactor (104-K12D02)
MFG #104-K12D02
Product Description:
104-K Mini Reversing Contactors, Screw Type Terminals, 12A, System Control Voltage: 110V 50Hz/120V 60Hz, 3 N.O. Main Contacts, 1 N.C. Auxiliary Contact
HESCO Part Number
AB104K12D02
UPC
662074500611
Manufacturer Part Number
104-K12D02
Manufacturer
Allen-Bradley
$414.27 / E
EACH
EACH
- Features
- Specifications
- Resources
- 12 A contact rating
- Storage: -55.80 (-67.176)
- 1 NC auxiliary contact configuration
- IP2X auxiliary contacts
- 5VA/1.8 W @ 50 Hz, 60 Hz, 50/60 Hz
- 35VA @ 50 Hz, 60 Hz, 50/60 Hz
- Class F per IEC 60085, Class 105 insulation system per UL 508
- (0.2.0.75) x Us @ 50 Hz, 60 Hz, 50/60 Hz
General Features
| Contact Rating | : | 12 A |
Power Electrical Characteristics | ||
| Auxiliary contact configuration | : | 1 NC |
| Coil consumption, hold-in | : | 5VA/1.8 W @ 50 Hz, 60 Hz, 50/60 Hz |
| Coil consumption, pick-up | : | 35VA @ 50 Hz, 60 Hz, 50/60 Hz |
| Coil insulation class | : | Class F per IEC 60085, Class 105 insulation system per UL 508 |
| Coil operating limits, dropout | : | (0.2.0.75) x Us @ 50 Hz, 60 Hz, 50/60 Hz |
| Coil operating limits, pick-up | : | (0.85.1.1) x Us @ 50 Hz, 60 Hz, 50/60 Hz |
| Coil operating time | : | 15.40 ms, closing delay @ AC |
| Contacts | : | 3 power poles with internal NC auxiliary contact |
| Current (Ie), max | : | 12 A |
| Current rating | : | 5 A |
| Function | : | Reversing contactor |
| Function or layout | : | Nothing specified |
| Rated coil frequency | : | AC 50/60 Hz, DC |
| Rated filament current | : | 9A @ 230/240V, AC-5b |
| Rating for switching AC motors | : | 3-poles: 5.5 kW @ 690V (AC-2, AC-3, AC-4), 3-phase (50 Hz) |
| Switching of DC loads | : | 3-poles in series: 9A @ 48/60V (Non-inductive or slightly inductive loads or resistance furnaces DC-1 at 60 °C) |
| Switching of lamps | : | Gas discharge lA, open: 18A @ 40°C, AC-5a |
| Terminal type | : | Screw terminals |
| Total power dissipation | : | DC control: 3.5 W @ 400V, AC-3, Ie |
| Voltage type for actuating | : | AC |
Construction | ||
| Optional accessories | : | Front-mount auxiliary contacts, surge suppressors, electronic timers, mechanical interlocks |
| Optional overload relays | : | Bimetallic |
Mechanical | ||
| Conductor cross section | : | 0.75.2.5 mm², 2 conductors @ main contact |
| Lifespan | : | Mechanical DC control: 15000000 ops |
| Recommended torque | : | 10.6 in-lb |
| Shock resistance | : | IEC 60068-2 |
| Vibration resistance | : | IEC 60068-2 |
Standards Protection | ||
| Ambient temperature | : | Storage: -55.80 (-67.176) |
| Auxiliary contacts | : | IP2X |
Overview | ||
| Standard Warranty Duration | : | 1 year |
Specifications | ||
| Build America, Buy America | : | No |
| Repair Options Available | : | No |
| General purpose current | : | 18 A per UL/CSA |
| Rated current | : | 9.6A @ 230V, 3-phase per UL/CSA |
| Rated isolation voltage | : | 690V per IEC |
| Rated operational current | : | 9.2A @ 500V, AC-4, 50 Hz, 3-phase, ambient temperature 60 °C |
| Rated operational power | : | 8.3 kW @ 240V, AC-1 (50 Hz), ambient temperature 40 °C |
| Rated power | : | 7.5Hp @ 575V, 3-phase per UL/CSA |
| Rated voltage | : | 690V @ AC, 50/60 Hz |
| Short time withstand | : | 96A @ 10s, 60 °C |
| Switching frequency, max | : | 250 ops/h, AC-4 |
| Country of Origin | : | Multiple |
- 12 A contact rating
- Storage: -55.80 (-67.176)
- 1 NC auxiliary contact configuration
- IP2X auxiliary contacts
- 5VA/1.8 W @ 50 Hz, 60 Hz, 50/60 Hz
- 35VA @ 50 Hz, 60 Hz, 50/60 Hz
- Class F per IEC 60085, Class 105 insulation system per UL 508
- (0.2.0.75) x Us @ 50 Hz, 60 Hz, 50/60 Hz
General Features
Contact Rating : 12 A Power Electrical Characteristics
Auxiliary contact configuration : 1 NC Coil consumption, hold-in : 5VA/1.8 W @ 50 Hz, 60 Hz, 50/60 Hz Coil consumption, pick-up : 35VA @ 50 Hz, 60 Hz, 50/60 Hz Coil insulation class : Class F per IEC 60085, Class 105 insulation system per UL 508 Coil operating limits, dropout : (0.2.0.75) x Us @ 50 Hz, 60 Hz, 50/60 Hz Coil operating limits, pick-up : (0.85.1.1) x Us @ 50 Hz, 60 Hz, 50/60 Hz Coil operating time : 15.40 ms, closing delay @ AC Contacts : 3 power poles with internal NC auxiliary contact Current (Ie), max : 12 A Current rating : 5 A Function : Reversing contactor Function or layout : Nothing specified Rated coil frequency : AC 50/60 Hz, DC Rated filament current : 9A @ 230/240V, AC-5b Rating for switching AC motors : 3-poles: 5.5 kW @ 690V (AC-2, AC-3, AC-4), 3-phase (50 Hz) Switching of DC loads : 3-poles in series: 9A @ 48/60V (Non-inductive or slightly inductive loads or resistance furnaces DC-1 at 60 °C) Switching of lamps : Gas discharge lA, open: 18A @ 40°C, AC-5a Terminal type : Screw terminals Total power dissipation : DC control: 3.5 W @ 400V, AC-3, Ie Voltage type for actuating : AC Construction
Optional accessories : Front-mount auxiliary contacts, surge suppressors, electronic timers, mechanical interlocks Optional overload relays : Bimetallic Mechanical
Conductor cross section : 0.75.2.5 mm², 2 conductors @ main contact Lifespan : Mechanical DC control: 15000000 ops Recommended torque : 10.6 in-lb Shock resistance : IEC 60068-2 Vibration resistance : IEC 60068-2 Standards Protection
Ambient temperature : Storage: -55.80 (-67.176) Auxiliary contacts : IP2X Overview
Standard Warranty Duration : 1 year Specifications
Build America, Buy America : No Repair Options Available : No General purpose current : 18 A per UL/CSA Rated current : 9.6A @ 230V, 3-phase per UL/CSA Rated isolation voltage : 690V per IEC Rated operational current : 9.2A @ 500V, AC-4, 50 Hz, 3-phase, ambient temperature 60 °C Rated operational power : 8.3 kW @ 240V, AC-1 (50 Hz), ambient temperature 40 °C Rated power : 7.5Hp @ 575V, 3-phase per UL/CSA Rated voltage : 690V @ AC, 50/60 Hz Short time withstand : 96A @ 10s, 60 °C Switching frequency, max : 250 ops/h, AC-4 Country of Origin : Multiple - Downloads
Spec Sheet

