300 NEMA Contactor, Size 1, 24V DC Electronic Coil, 3 Poles, 1 N.O. Auxiliary Contact included, Screw Terminals
HESCO Part Number
AB300BOEJ930
UPC
612598653508
Manufacturer Part Number
300-BOEJ930
Manufacturer
Allen-Bradley
NEMA Size 1 300 AC Contactor (300-BOEJ930)
MFG #300-BOEJ930
Product Description:
300 NEMA Contactor, Size 1, 24V DC Electronic Coil, 3 Poles, 1 N.O. Auxiliary Contact included, Screw Terminals
HESCO Part Number
AB300BOEJ930
UPC
612598653508
Manufacturer Part Number
300-BOEJ930
Manufacturer
Allen-Bradley
$870.64 / E
EACH
EACH
- Features
- Specifications
- Resources
- Australian RCM
- Open Style mounting
- UKCA DOC
- 3000 m altitude, max
- Storage: -60.80 °C (-76.176 °F)
- Category B according to IEC 60947-1, Annex Q
- 24V 50/60 Hz electronic coil with electronic interface
- Main contacts, 2 conductor: 2.5.10 mm²
- 10 mm² conductor size
- LRA: 270 A @ 440-480V AC (3-phase), UL/CSA HVAC applications
General Features
| Mounting | : | Open Style |
Power Electrical Characteristics | ||
| Coil voltage | : | 24V 50/60 Hz electronic coil with electronic interface |
| Conductor size | : | 10 mm² |
| Definite purpose rating | : | LRA: 270 A @ 440-480V AC (3-phase), UL/CSA HVAC applications |
| DIN fuses (gG) current rating | : | Type 2 (IEC 60947-4-1): 62A @ 400V, 100 kA available fault current |
| Electromagnetic compatibility | : | IEC 60947-1 - Environment A |
| Energy-efficient coil, hold-in | : | 1.7VA/1.7 W @ 24-60V AC, 20-60V DC |
| Energy-efficient coil, pick-up | : | 16VA/12.16 W @ 24-60V AC, 20-60V DC |
| Hp rating, max | : | 7.5Hp @ 230V (60 Hz), 3-phase (Full-load current must not exceed continuous Aere) |
| Insulation class of the coil | : | Class F per IEC 60947-4-1 |
| MCCB current rating | : | Type 2 (IEC 60947-4-1): 56A @ 400V, 70 kA available fault current |
| NEMA size | : | Size 1 |
| Number of power poles | : | Three pole + 1 NO auxiliary hold-in contact |
| Operating limits, dropout | : | ≤0.60 x Us @ DC control |
| Operating limits, pick-up | : | (0.85.1.1) x Us @ 50/60 Hz |
| Operating time, closing delay | : | 40.95 ms (Standard coil) |
| Operating time, opening delay | : | 17.29 ms (High energy-efficient coil) |
| Power dissipation | : | 2.4 W per pole @ 400V, AC-1, Ie (4 pole) |
| Standard coil, hold-in | : | 2.2VA/2 W @ 48.130V AC/DC |
| Standard coil, pick-up | : | 50VA/50 W @ 48.130V AC/DC |
| Switching of DC loads | : | 4-Poles in series: 45A @ 220V (Non-inductive or slightly inductive loads or resistance furnaces DC-1 at 60 °C) |
| Switching of lighting loads | : | Tungsten lA, 3-phase (break all lines) (UL/CSA): 45A @ 600V |
| Total power dissipation | : | 4.7 W @ 400V, AC-3, Ie, AC/DC control (120-250V), 4 pole |
| UL class RK5 fuses rating | : | Type 1 combination (UL60947 and CSA 22.2 No.14): 60A @ 600V, 5 kA available fault current |
| Voltage type for actuating | : | AC |
Construction | ||
| Enclosure | : | Open Type |
| Lug | : | No built-in lug |
Mechanical | ||
| Conductor cross section | : | Main contacts, 2 conductor: 2.5.10 mm² |
| Protection class | : | Contactor main contacts: IP2X |
| Recommended torque | : | Main contacts: 2.5 Nm |
| Shock resistance | : | IEC 60068-2-27 |
| Switching frequency, max | : | 600 cycles/h, AC-1 |
| Vibration resistance | : | IEC 60068-2-6 |
| Weight | : | AC/DC (Electronic): 0.48 kg (1.06 lbs.) |
Standards Protection | ||
| Altitude, max | : | 3000 m |
| Ambient temperature | : | Storage: -60.80 °C (-76.176 °F) |
| Climatic withstand | : | Category B according to IEC 60947-1, Annex Q |
Overview | ||
| Standard Warranty Duration | : | 1 year |
Specifications | ||
| Build America, Buy America | : | No |
| Repair Options Available | : | No |
| Depth | : | 4.06 mm |
| General purpose current | : | 24A @ 600V per UL/CSA |
| Height | : | 3.19 mm |
| Rated isolation voltage | : | 690V per IEC |
| Rated operational current | : | 25.3 A @ 200-208V, 3-phase per UL/CSA |
| Rated operational power | : | 7.5 Hp @ 220-240V, 3-phase per UL/CSA |
| Rated voltage | : | 24, 48, 110, 220, 440V DC |
| Short time withstand | : | 3-Poles: 700A @ 1s, 40 °C |
| Width | : | 2.12 mm |
| Country of Origin | : | Switzerland |
- Australian RCM
- Open Style mounting
- UKCA DOC
- 3000 m altitude, max
- Storage: -60.80 °C (-76.176 °F)
- Category B according to IEC 60947-1, Annex Q
- 24V 50/60 Hz electronic coil with electronic interface
- Main contacts, 2 conductor: 2.5.10 mm²
- 10 mm² conductor size
- LRA: 270 A @ 440-480V AC (3-phase), UL/CSA HVAC applications
General Features
Mounting : Open Style Power Electrical Characteristics
Coil voltage : 24V 50/60 Hz electronic coil with electronic interface Conductor size : 10 mm² Definite purpose rating : LRA: 270 A @ 440-480V AC (3-phase), UL/CSA HVAC applications DIN fuses (gG) current rating : Type 2 (IEC 60947-4-1): 62A @ 400V, 100 kA available fault current Electromagnetic compatibility : IEC 60947-1 - Environment A Energy-efficient coil, hold-in : 1.7VA/1.7 W @ 24-60V AC, 20-60V DC Energy-efficient coil, pick-up : 16VA/12.16 W @ 24-60V AC, 20-60V DC Hp rating, max : 7.5Hp @ 230V (60 Hz), 3-phase (Full-load current must not exceed continuous Aere) Insulation class of the coil : Class F per IEC 60947-4-1 MCCB current rating : Type 2 (IEC 60947-4-1): 56A @ 400V, 70 kA available fault current NEMA size : Size 1 Number of power poles : Three pole + 1 NO auxiliary hold-in contact Operating limits, dropout : ≤0.60 x Us @ DC control Operating limits, pick-up : (0.85.1.1) x Us @ 50/60 Hz Operating time, closing delay : 40.95 ms (Standard coil) Operating time, opening delay : 17.29 ms (High energy-efficient coil) Power dissipation : 2.4 W per pole @ 400V, AC-1, Ie (4 pole) Standard coil, hold-in : 2.2VA/2 W @ 48.130V AC/DC Standard coil, pick-up : 50VA/50 W @ 48.130V AC/DC Switching of DC loads : 4-Poles in series: 45A @ 220V (Non-inductive or slightly inductive loads or resistance furnaces DC-1 at 60 °C) Switching of lighting loads : Tungsten lA, 3-phase (break all lines) (UL/CSA): 45A @ 600V Total power dissipation : 4.7 W @ 400V, AC-3, Ie, AC/DC control (120-250V), 4 pole UL class RK5 fuses rating : Type 1 combination (UL60947 and CSA 22.2 No.14): 60A @ 600V, 5 kA available fault current Voltage type for actuating : AC Construction
Enclosure : Open Type Lug : No built-in lug Mechanical
Conductor cross section : Main contacts, 2 conductor: 2.5.10 mm² Protection class : Contactor main contacts: IP2X Recommended torque : Main contacts: 2.5 Nm Shock resistance : IEC 60068-2-27 Switching frequency, max : 600 cycles/h, AC-1 Vibration resistance : IEC 60068-2-6 Weight : AC/DC (Electronic): 0.48 kg (1.06 lbs.) Standards Protection
Altitude, max : 3000 m Ambient temperature : Storage: -60.80 °C (-76.176 °F) Climatic withstand : Category B according to IEC 60947-1, Annex Q Overview
Standard Warranty Duration : 1 year Specifications
Build America, Buy America : No Repair Options Available : No Depth : 4.06 mm General purpose current : 24A @ 600V per UL/CSA Height : 3.19 mm Rated isolation voltage : 690V per IEC Rated operational current : 25.3 A @ 200-208V, 3-phase per UL/CSA Rated operational power : 7.5 Hp @ 220-240V, 3-phase per UL/CSA Rated voltage : 24, 48, 110, 220, 440V DC Short time withstand : 3-Poles: 700A @ 1s, 40 °C Width : 2.12 mm Country of Origin : Switzerland - Downloads
Spec Sheet
General 1