Powermonitor 500 Power Meter (1420-V2A)
MFG #1420-V2A
$1,723.40 / E
EACH
EACH
Product Description:
PowerMonitor 500, 600V AC, 2 Analog Outputs
HESCO Part Number
AB1420V2A
UPC
885630236612
Manufacturer Part Number
1420-V2A
Manufacturer
Allen-Bradley
Powermonitor 500 Power Meter (1420-V2A)
MFG #1420-V2A
Product Description:
PowerMonitor 500, 600V AC, 2 Analog Outputs
HESCO Part Number
AB1420V2A
UPC
885630236612
Manufacturer Part Number
1420-V2A
Manufacturer
Allen-Bradley
$1,723.40 / E
EACH
EACH
- Features
- Specifications
- Resources
- 1.00%
- Alarm
- 45-65Hz frequency rating
- Built-in LCD interface
- 2 Digital Relays output
- Ampere meter
- Analog output
- Apparent power consumption
General Features
| Accuracy | : | 1.00% |
| Alarm | : | true |
| Frequency Rating | : | 45-65Hz |
| Interface | : | Built-in LCD |
| Output | : | 2 Digital Relays |
| Class | : | Class 1 (kWh) according to EN62053-21,. Class B (kWh) according to EN50470-3,. Class 2 (kVARh) according to EN62053-23 |
| Configurable alarms | : | true |
| Configurable via software tool | : | true |
| configurable virtual alarms | : | Up to four |
| Energy value display | : | Ten digits and the plus/minus sign |
| Front protection degree | : | IP65, NEMA 4X, NEMA 12 |
| Height | : | Front dimensions: 96 mm |
| Metering values display | : | Four rows with 4 digits |
| Real-time clock function | : | true |
| Run hours counter | : | 8+2 digits |
| Single phase variables | : | V(L-L), V(L-N), A(L), An (calculated), VA, W, VAR, power factor |
| Three-phase (system) variables | : | V(L-L), V(L-N), A, VA, W, VAR, power factor, frequency |
| Universal power supply | : | 120/240V AC 50/60 Hz or 120/240V DC |
| Width | : | Front dimensions: 96 mm |
Inputs Outputs Io | ||
| Configuration | : | By using the front keypad |
| Current sensing | : | Nominal: 5 A |
| Load | : | ≤ 600 Ω |
| Number of outputs | : | 2 |
| Range | : | Maximum @ 0 to 20 mA |
| Response time | : | ≤ 400 ms typical (filter excluded) |
| Ripple | : | ≤ 1% (according to IEC 60688-1, EN 60688-1) |
| Scaling factor | : | Progmable within the whole range of retransmission, it allows the retransmission management of all values from 0 to 20 mA DC |
| Signal retransmission | : | The signal output can be connected to any instantaneous variable |
| Total temperature drift | : | ≤ 500 ppm/°C |
| Voltage sensing | : | Nominal: 400V AC LN, 600V AC LL Range: 160 to 480V AC LN RMS, 277 to 830V AC LL RMS |
Power Electrical Characteristics | ||
| Ampere meter | : | true |
| Blind power meter | : | true |
| Frequency meter | : | true |
| Pulse counter | : | true |
| Voltmeter | : | true |
Measurement Parameters | ||
| Crest factor | : | ≤3 (15 A max peak) |
| Current | : | true |
| Demand power factor | : | true |
| Frequency | : | Hz: Yes |
| Power factor | : | PF: Yes |
| Voltage | : | true |
Environmental Operating Conditions | ||
| Burst | : | On current and voltage measuring inputs circuit: 4 kV |
| Dielectric strength | : | 4 kV AC rms for 1 min |
| Electrostatic discharge | : | 15 kV air discharge |
| EMC | : | According to EN62052-11 |
| Installation category | : | Cat. III (IEC60664, EN60664) |
| Noise rejection CMRR | : | 100 dB, 48 to 62 Hz |
| Operating temperature | : | -25 to +40 °C (-13 to +104 °F) (R.H. from 0…90% noncondensing @ 40 °C) according to EN62053-21, EN50470-1 and EN62053- 23 |
| Radio frequency suppression | : | According to CISPR 22 |
| Storage temperature | : | -30 to +70 °C (-22 to +158 °F) (R.H.P178 < 90% noncondensing @ 40 °C) according to EN62053-21, EN50470-1 and EN62053- 23 |
| Surge | : | On current and voltage measuring inputs circuit: 4 kV, on ‘L’ auxiliary power supply input: 1 kV |
Housing Din | ||
| Depth behind panel | : | Maximum @ 81.7 mm (3.2 in.) |
| Material | : | ABS, self-extinguishing: UL 94 V-0 |
| Mounting | : | Panel mounting |
| Pollution degree | : | 2 |
| Screw terminals | : | IP20 |
| Weight | : | Approx 400 g (0.88 lb) (packing included) |
Overview | ||
| Standard Warranty Duration | : | 1 year |
Specifications | ||
| Build America, Buy America | : | No |
| Repair Options Available | : | No |
| Analog output | : | true |
| Apparent power consumption | : | true |
| Apparent power | : | true |
| Current range | : | 5 A nominal (6 A maximum) |
| Demand | : | true |
| Dimensions | : | Module holder: 96 x 96 x 50 mm (3.78 x 3.78 x 1.97 in.), Digital and analog output type modules: 89.5 x 63 x 16 mm (3.52 x 2.48 x 0.63 in.), Serial and Ethernet Communication type modules: 89.5 x 63 x 20 mm (3.52 x 2.48 x 0.79 in.) |
| Energy measurements | : | kWh and kVARh |
| Reactive energy | : | Class 2 according to EN62053-23, ANSI C12.1 |
| Reactive power consumption | : | true |
| Reactive power | : | true |
| Real energy | : | Class 1 according to EN62053-21, ANSI C12.1 Class B according to EN50470-3 |
| Real power consumption | : | true |
| Real power | : | true |
| Country of Origin | : | Italy |
Standard Compliance | ||
| Cable cross-section area | : | 2.5 mm2 AWG) max, Screw tightening torque: 0.4 N. m min/0.8 N. m max, Suggested screw tightening torque: 0.5 N. m |
| Connections | : | Screw-type |
General Specifications | ||
| Current all models | : | From 0.01 to 0.25 A: ±(1.0% of reading (RDG) + 2 digits From 0.25 to 6 A: ±(0.5% RDG +2 digits) |
| Current sensing model | : | Inominal: 5 A, Imaximum: 6A |
| Line-line RMS | : | Maximum @ 277 to 830V AC |
| Line-line voltage | : | In the range Vnom: ±(1.0% RDG +1 digit) |
| Line-neutral RMS | : | Maximum @ 160 to 480V AC |
| Line-neutral voltage | : | In the range Vnom: ±(0.5% RDG +1 digit) |
| Real and apparent power | : | From 0.05 to 0.25 A, PF 1: ±(2% RDG +1 digit) From 0.25 to 6A, PF 0.5L, PF1, PF 0.8C: ±(1.0% RDG+1 digit) |
| Start up current | : | 5 |
Inputoutput Specifications | ||
| Control power | : | Range: 100 to 240V AC (48 to 62 Hz) |
| Coupling type | : | With CTs |
| Current overloads | : | 6 A, at 50/60 Hz, Continuous |
| Current type | : | Galvanic insulation with built-in CTs |
| Energy additional errors | : | According to EN62053-21 ANSI C12.1, influence quantities Class B according to EN50470-3, EN62053-23 |
| Input impedance | : | 5(6)A, < 0.2VA |
| Method | : | True RMS measurements of distorted wave forms |
| Rated inputs | : | System type: 1, 2, or 3-phase |
| Sampling rate | : | 3840 sAles/s at 60 Hz, 3200 sAles/s at 50 Hz |
| Temperature drift | : | ≤ 200 ppm/°C |
| Voltage overloads | : | 2 × Vnom (where Vnom is the nominal voltage of the module), for 500 ms |
- 1.00%
- Alarm
- 45-65Hz frequency rating
- Built-in LCD interface
- 2 Digital Relays output
- Ampere meter
- Analog output
- Apparent power consumption
General Features
Accuracy : 1.00% Alarm : true Frequency Rating : 45-65Hz Interface : Built-in LCD Output : 2 Digital Relays Class : Class 1 (kWh) according to EN62053-21,. Class B (kWh) according to EN50470-3,. Class 2 (kVARh) according to EN62053-23 Configurable alarms : true Configurable via software tool : true configurable virtual alarms : Up to four Energy value display : Ten digits and the plus/minus sign Front protection degree : IP65, NEMA 4X, NEMA 12 Height : Front dimensions: 96 mm Metering values display : Four rows with 4 digits Real-time clock function : true Run hours counter : 8+2 digits Single phase variables : V(L-L), V(L-N), A(L), An (calculated), VA, W, VAR, power factor Three-phase (system) variables : V(L-L), V(L-N), A, VA, W, VAR, power factor, frequency Universal power supply : 120/240V AC 50/60 Hz or 120/240V DC Width : Front dimensions: 96 mm Inputs Outputs Io
Configuration : By using the front keypad Current sensing : Nominal: 5 A Load : ≤ 600 Ω Number of outputs : 2 Range : Maximum @ 0 to 20 mA Response time : ≤ 400 ms typical (filter excluded) Ripple : ≤ 1% (according to IEC 60688-1, EN 60688-1) Scaling factor : Progmable within the whole range of retransmission, it allows the retransmission management of all values from 0 to 20 mA DC Signal retransmission : The signal output can be connected to any instantaneous variable Total temperature drift : ≤ 500 ppm/°C Voltage sensing : Nominal: 400V AC LN, 600V AC LL Range: 160 to 480V AC LN RMS, 277 to 830V AC LL RMS Power Electrical Characteristics
Ampere meter : true Blind power meter : true Frequency meter : true Pulse counter : true Voltmeter : true Measurement Parameters
Crest factor : ≤3 (15 A max peak) Current : true Demand power factor : true Frequency : Hz: Yes Power factor : PF: Yes Voltage : true Environmental Operating Conditions
Burst : On current and voltage measuring inputs circuit: 4 kV Dielectric strength : 4 kV AC rms for 1 min Electrostatic discharge : 15 kV air discharge EMC : According to EN62052-11 Installation category : Cat. III (IEC60664, EN60664) Noise rejection CMRR : 100 dB, 48 to 62 Hz Operating temperature : -25 to +40 °C (-13 to +104 °F) (R.H. from 0…90% noncondensing @ 40 °C) according to EN62053-21, EN50470-1 and EN62053- 23 Radio frequency suppression : According to CISPR 22 Storage temperature : -30 to +70 °C (-22 to +158 °F) (R.H.P178 < 90% noncondensing @ 40 °C) according to EN62053-21, EN50470-1 and EN62053- 23 Surge : On current and voltage measuring inputs circuit: 4 kV, on ‘L’ auxiliary power supply input: 1 kV Housing Din
Depth behind panel : Maximum @ 81.7 mm (3.2 in.) Material : ABS, self-extinguishing: UL 94 V-0 Mounting : Panel mounting Pollution degree : 2 Screw terminals : IP20 Weight : Approx 400 g (0.88 lb) (packing included) Overview
Standard Warranty Duration : 1 year Specifications
Build America, Buy America : No Repair Options Available : No Analog output : true Apparent power consumption : true Apparent power : true Current range : 5 A nominal (6 A maximum) Demand : true Dimensions : Module holder: 96 x 96 x 50 mm (3.78 x 3.78 x 1.97 in.), Digital and analog output type modules: 89.5 x 63 x 16 mm (3.52 x 2.48 x 0.63 in.), Serial and Ethernet Communication type modules: 89.5 x 63 x 20 mm (3.52 x 2.48 x 0.79 in.) Energy measurements : kWh and kVARh Reactive energy : Class 2 according to EN62053-23, ANSI C12.1 Reactive power consumption : true Reactive power : true Real energy : Class 1 according to EN62053-21, ANSI C12.1 Class B according to EN50470-3 Real power consumption : true Real power : true Country of Origin : Italy Standard Compliance
Cable cross-section area : 2.5 mm2 AWG) max, Screw tightening torque: 0.4 N. m min/0.8 N. m max, Suggested screw tightening torque: 0.5 N. m Connections : Screw-type General Specifications
Current all models : From 0.01 to 0.25 A: ±(1.0% of reading (RDG) + 2 digits From 0.25 to 6 A: ±(0.5% RDG +2 digits) Current sensing model : Inominal: 5 A, Imaximum: 6A Line-line RMS : Maximum @ 277 to 830V AC Line-line voltage : In the range Vnom: ±(1.0% RDG +1 digit) Line-neutral RMS : Maximum @ 160 to 480V AC Line-neutral voltage : In the range Vnom: ±(0.5% RDG +1 digit) Real and apparent power : From 0.05 to 0.25 A, PF 1: ±(2% RDG +1 digit) From 0.25 to 6A, PF 0.5L, PF1, PF 0.8C: ±(1.0% RDG+1 digit) Start up current : 5 Inputoutput Specifications
Control power : Range: 100 to 240V AC (48 to 62 Hz) Coupling type : With CTs Current overloads : 6 A, at 50/60 Hz, Continuous Current type : Galvanic insulation with built-in CTs Energy additional errors : According to EN62053-21 ANSI C12.1, influence quantities Class B according to EN50470-3, EN62053-23 Input impedance : 5(6)A, < 0.2VA Method : True RMS measurements of distorted wave forms Rated inputs : System type: 1, 2, or 3-phase Sampling rate : 3840 sAles/s at 60 Hz, 3200 sAles/s at 50 Hz Temperature drift : ≤ 200 ppm/°C Voltage overloads : 2 × Vnom (where Vnom is the nominal voltage of the module), for 500 ms - Downloads
User Manual