IEC 12 A Reversing Contactor (104-C12KJ22)
MFG #104-C12KJ22
$551.57 / E
EACH
EACH
Product Description:
104-C Reversing Contactors, 12A, Line Side, 24V 50/60Hz, 1 N.O. 1 N.C
HESCO Part Number
AB104C12KJ22
UPC
662468987165
Manufacturer Part Number
104-C12KJ22
Manufacturer
Allen-Bradley
IEC 12 A Reversing Contactor (104-C12KJ22)
MFG #104-C12KJ22
Product Description:
104-C Reversing Contactors, 12A, Line Side, 24V 50/60Hz, 1 N.O. 1 N.C
HESCO Part Number
AB104C12KJ22
UPC
662468987165
Manufacturer Part Number
104-C12KJ22
Manufacturer
Allen-Bradley
$551.57 / E
EACH
EACH
- Features
- Specifications
- Resources
- IECEE Scheme
- 24V 50/60 Hz coil voltage
- 12 A maximum load current
- Storage: -55.80 (-67.176)
- 1 NO, 1 NC auxiliary contacts
- Type 2 : 25A @ 415V, 65 kA available fault current
- 500 µF @ short-circuit current of 20 kA
- 9.5VA/2.7 W @ 50 Hz, 60 Hz, 50/60 Hz
- 14/22 W @ DC (electronic-EA) coil consumption pick-up
General Features
| Coil Voltage | : | 24V 50/60 Hz |
| Maximum Load Current | : | 12 A |
Power Electrical Characteristics | ||
| Capacitance, max | : | 500 µF @ short-circuit current of 20 kA |
| Coil consumption, hold-in | : | 9.5VA/2.7 W @ 50 Hz, 60 Hz, 50/60 Hz |
| Coil consumption, pick-up | : | 75VA @ 50 Hz, 60 Hz, 50/60 Hz |
| Coil insulation class | : | Class F per IEC 60085, UL Class 105 |
| Contacts | : | 3 power poles with internal NO or NC auxiliary contact or 4 power poles (9.23 A), Optional front-or side mounted 1-2 or 4-pole external auxiliary contact block |
| Conventional coil type | : | true |
| Cross section per UL/CSA | : | 16 |
| Current (Ie), max | : | 97 A |
| Electronic-EI coil type | : | true |
| Function | : | Reversing contactor |
| Operating limits, dropout | : | (0.3.0.6) x Us @ 50 Hz, 60 Hz, 50/60 Hz |
| Operating limits, pick-up | : | (0.85.1.1) x Us @ 50 Hz, 60 Hz, 50/60 Hz |
| Operating time | : | 15…30 ms @ AC closing delay |
| Power dissipation | : | 1.2 W @ 400V, AC-3, Ie |
| Rated coil frequency | : | AC 50/60 Hz, DC |
| Rated filament current | : | 16A @ 230/240V, AC-5b |
| Rating for switching AC motors | : | 3-poles: 7.5Hp @ 460V (AC-2, AC-3, AC-4), 3-phase (60 Hz) |
| Switching frequency, max | : | 250 ops/h |
| Switching of DC loads | : | 3-Poles in series: 6A @ 220V (Shunt-wound motors starting, reverse current braking, reversing, stepping DC-3 at 60 °C) |
| Switching of lamps | : | Gas discharge lA, open: 25A @ 40°C (104 °F), AC-5a |
| Switching of motor load | : | 14A @ 230V, AC-7b per IEC 61095 (50 Hz) |
| Total power dissipation | : | DC control (electronic): 2.9 W @ 400V, AC-3, Ie |
| Voltage type for actuating | : | AC |
Construction | ||
| Optional accessories | : | Front or side-mount auxiliary contacts, Surge suppressors, Electronic or pneumatic timers, Mechanical interlocks, Mechanical latches |
| Optional overload relays | : | Electronic or bimetallic |
| Options | : | Empty |
Mechanical | ||
| Coil termination | : | Line side connection |
| Conductor cross section | : | Main contacts, 2 conductor: 1…4 mm² |
| Lifespan | : | Mechanical DC control: 13000000 ops |
| Recommended torque | : | 9 in-lb |
| Shock resistance | : | IEC 60068-2-27 |
| Vibration resistance | : | IEC 60068-2-6 |
| Weight | : | 0.93 kg (2.05 lbs) reverse @ DC (electronic-EW, EY, ED, EA) |
Standards Protection | ||
| Ambient temperature | : | Storage: -55.80 (-67.176) |
| Auxiliary contacts | : | 1 NO, 1 NC |
Overview | ||
| Standard Warranty Duration | : | 1 year |
Specifications | ||
| Build America, Buy America | : | Yes |
| Repair Options Available | : | No |
| BS88 fuses current rating | : | Type 2 : 25A @ 415V, 65 kA available fault current |
| Coil consumption pick-up | : | 14/22 W @ DC (electronic-EA) |
| Depth | : | 104.48 mm |
| General purpose current | : | 25 A per UL/CSA |
| Height | : | 80.77 mm |
| Rated current | : | 9.8A @ 115V, 1-phase per UL/CSA |
| Rated isolation voltage | : | 690V @ IEC |
| Rated operational current | : | 9.6A @ 230V, 3-phase per UL/CSA |
| Rated operational power | : | 7.5 kW @230V, Star-Delta starting (50 Hz) |
| Rated power | : | 7.5Hp @ 460V, 3-phase per UL/CSA |
| Rated voltage | : | 690V @ AC, 50/60 Hz |
| Short time withstand | : | 170A @ 10s, 60 °C |
| Width | : | 117 mm |
| Country of Origin | : | Multiple |
- IECEE Scheme
- 24V 50/60 Hz coil voltage
- 12 A maximum load current
- Storage: -55.80 (-67.176)
- 1 NO, 1 NC auxiliary contacts
- Type 2 : 25A @ 415V, 65 kA available fault current
- 500 µF @ short-circuit current of 20 kA
- 9.5VA/2.7 W @ 50 Hz, 60 Hz, 50/60 Hz
- 14/22 W @ DC (electronic-EA) coil consumption pick-up
General Features
Coil Voltage : 24V 50/60 Hz Maximum Load Current : 12 A Power Electrical Characteristics
Capacitance, max : 500 µF @ short-circuit current of 20 kA Coil consumption, hold-in : 9.5VA/2.7 W @ 50 Hz, 60 Hz, 50/60 Hz Coil consumption, pick-up : 75VA @ 50 Hz, 60 Hz, 50/60 Hz Coil insulation class : Class F per IEC 60085, UL Class 105 Contacts : 3 power poles with internal NO or NC auxiliary contact or 4 power poles (9.23 A), Optional front-or side mounted 1-2 or 4-pole external auxiliary contact block Conventional coil type : true Cross section per UL/CSA : 16 Current (Ie), max : 97 A Electronic-EI coil type : true Function : Reversing contactor Operating limits, dropout : (0.3.0.6) x Us @ 50 Hz, 60 Hz, 50/60 Hz Operating limits, pick-up : (0.85.1.1) x Us @ 50 Hz, 60 Hz, 50/60 Hz Operating time : 15…30 ms @ AC closing delay Power dissipation : 1.2 W @ 400V, AC-3, Ie Rated coil frequency : AC 50/60 Hz, DC Rated filament current : 16A @ 230/240V, AC-5b Rating for switching AC motors : 3-poles: 7.5Hp @ 460V (AC-2, AC-3, AC-4), 3-phase (60 Hz) Switching frequency, max : 250 ops/h Switching of DC loads : 3-Poles in series: 6A @ 220V (Shunt-wound motors starting, reverse current braking, reversing, stepping DC-3 at 60 °C) Switching of lamps : Gas discharge lA, open: 25A @ 40°C (104 °F), AC-5a Switching of motor load : 14A @ 230V, AC-7b per IEC 61095 (50 Hz) Total power dissipation : DC control (electronic): 2.9 W @ 400V, AC-3, Ie Voltage type for actuating : AC Construction
Optional accessories : Front or side-mount auxiliary contacts, Surge suppressors, Electronic or pneumatic timers, Mechanical interlocks, Mechanical latches Optional overload relays : Electronic or bimetallic Options : Empty Mechanical
Coil termination : Line side connection Conductor cross section : Main contacts, 2 conductor: 1…4 mm² Lifespan : Mechanical DC control: 13000000 ops Recommended torque : 9 in-lb Shock resistance : IEC 60068-2-27 Vibration resistance : IEC 60068-2-6 Weight : 0.93 kg (2.05 lbs) reverse @ DC (electronic-EW, EY, ED, EA) Standards Protection
Ambient temperature : Storage: -55.80 (-67.176) Auxiliary contacts : 1 NO, 1 NC Overview
Standard Warranty Duration : 1 year Specifications
Build America, Buy America : Yes Repair Options Available : No BS88 fuses current rating : Type 2 : 25A @ 415V, 65 kA available fault current Coil consumption pick-up : 14/22 W @ DC (electronic-EA) Depth : 104.48 mm General purpose current : 25 A per UL/CSA Height : 80.77 mm Rated current : 9.8A @ 115V, 1-phase per UL/CSA Rated isolation voltage : 690V @ IEC Rated operational current : 9.6A @ 230V, 3-phase per UL/CSA Rated operational power : 7.5 kW @230V, Star-Delta starting (50 Hz) Rated power : 7.5Hp @ 460V, 3-phase per UL/CSA Rated voltage : 690V @ AC, 50/60 Hz Short time withstand : 170A @ 10s, 60 °C Width : 117 mm Country of Origin : Multiple - Downloads
Spec Sheet