Motor Protection Circuit-Breaker (140M-C2E-B16)
MFG #140M-C2E-B16
$325.28 / E
EACH
EACH
Product Description:
Circuit-Breaker, Motor Protection, 1 - 1.6A, MxRtg MCPs(no OvPrt)is 1200.0A, Frame Size C, Standard Breaking Capacity, No Bus Bar Mount, 1.6 A, No Knob Adaptor Modification, for Thermal Overloads, None, None, Std Mgntc Trp (Fxd at 13 x le), None, None, None, Trigger Constraints, None, No Options Right
HESCO Part Number
AB140MC2EB16
UPC
662468964326
Manufacturer Part Number
140M-C2E-B16
Manufacturer
Allen-Bradley
Motor Protection Circuit-Breaker (140M-C2E-B16)
MFG #140M-C2E-B16
Product Description:
Circuit-Breaker, Motor Protection, 1 - 1.6A, MxRtg MCPs(no OvPrt)is 1200.0A, Frame Size C, Standard Breaking Capacity, No Bus Bar Mount, 1.6 A, No Knob Adaptor Modification, for Thermal Overloads, None, None, Std Mgntc Trp (Fxd at 13 x le), None, None, None, Trigger Constraints, None, No Options Right
HESCO Part Number
AB140MC2EB16
UPC
662468964326
Manufacturer Part Number
140M-C2E-B16
Manufacturer
Allen-Bradley
$325.28 / E
EACH
EACH
- Features
- Specifications
- Resources
- 1 - 1.6A,MxRtg MCPs(no OvPrt)is 1200.0A
- Mtr Prt Circuit Breaker application
- -25 °C ambient operating temperature
- -40 °C ambient storage temperature
- -20 °C ambient temperature compensation
- Auxiliary circuits/overvoltage category-inv: 6kV/III @ rated impulse withstand voltage (Uimp)
- Standard breaking capacity
- 100-K05: UL-508-Type F combination motor controller
General Features
| Amperage Rating | : | 1 - 1.6A,MxRtg MCPs(no OvPrt)is 1200.0A |
| Application | : | Mtr Prt Circuit Breaker |
Power Electrical Characteristics | ||
| Auxiliary circuits/overvoltage category-inv | : | 6kV/III @ rated impulse withstand voltage (Uimp) |
| Current range | : | 1.1.6 A |
| Electrical life cycle | : | (Ie max.) 100000 ops |
| Hp rating, max | : | 1Hp @ 575V, 3-phase |
| KW rating, max | : | 1.1 kW @ 690V (AC-3), 3-phase |
| Magnetic release current | : | Fixed setting 13.14 x Ie max. Ie max. = maximum values of setting ranges, (±20 %) |
| Magnetic trip current | : | 21 A |
| Main circuits/overvoltage category | : | 6kV/III @ rated impulse withstand voltage (Uimp) |
| Number of poles | : | 3 |
| Phase failure sensitive | : | true |
| Phase loss protection | : | Differential release |
| Rated frequency | : | 50/60 Hz |
| Rated operating voltage | : | 230 A |
| Rated operating voltage, max | : | 690V per IEC, SEV, VDE0660 |
| Rated supply current | : | 0.1 A |
| Rated thermal current | : | 0.1.32A @ 60°C ambient temperature (Ith)-inv |
| Switching frequency, max | : | 25 ops/h |
| Switch off technique | : | Thermomagnetic |
| Trip class | : | 10 |
| Type of control element | : | Turn button |
| With thermal protection | : | true |
Construction | ||
| Contactor size, min-inv | : | 100-K05: UL-508-Type F combination motor controller |
| Device construction | : | Built-in device fixed built-in technique |
| Frame size | : | Frame size C, 32 A |
Mechanical | ||
| Breaking capacity | : | Standard breaking capacity |
| Factory option | : | No circuit-breaker auxiliary or trip contacts |
| Mechanical life operations | : | 100000 /h |
| Protection type | : | Adjustable thermal/fixed magnetic (13 x In) |
| Shock resistance | : | Transport (60068-2-27): 30 G, 11 ms, all axes |
| Terminal type | : | Screw connection |
| Vibration resistance | : | ops (60068-2-6): 5 G |
| Weight | : | 317 lb |
Standards Protection | ||
| Ambient operating temperature | : | -25 °C |
| Ambient storage temperature | : | -40 °C |
| Ambient temperature compensation | : | -20 °C |
| Dependence on temperature | : | No current reduction @ 60 °C-inv |
| Dry heat | : | 100 °C, relative humidity < 50 %, 7 d (60086-2-2)-inv |
| Moisture change climate | : | 23 °C/83 % relative humidity and 40 °C/92 % relative humidity, 56 cycles (600068-2-30)-inv |
| Moisture heat | : | 40 °C, relative humidity 93 %, 56 d (60068-2-3)-inv |
| Pollution degree | : | 3 |
| Site altitude | : | To 2000 N.N.(m) |
Overview | ||
| Standard Warranty Duration | : | 1 year |
Specifications | ||
| Build America, Buy America | : | No |
| Repair Options Available | : | No |
| Degree of protection | : | IP2X |
| Depth | : | 74.5 mm |
| Height | : | 90 mm |
| Width | : | 45 mm |
| Country of Origin | : | Switzerland |
- 1 - 1.6A,MxRtg MCPs(no OvPrt)is 1200.0A
- Mtr Prt Circuit Breaker application
- -25 °C ambient operating temperature
- -40 °C ambient storage temperature
- -20 °C ambient temperature compensation
- Auxiliary circuits/overvoltage category-inv: 6kV/III @ rated impulse withstand voltage (Uimp)
- Standard breaking capacity
- 100-K05: UL-508-Type F combination motor controller
General Features
Amperage Rating : 1 - 1.6A,MxRtg MCPs(no OvPrt)is 1200.0A Application : Mtr Prt Circuit Breaker Power Electrical Characteristics
Auxiliary circuits/overvoltage category-inv : 6kV/III @ rated impulse withstand voltage (Uimp) Current range : 1.1.6 A Electrical life cycle : (Ie max.) 100000 ops Hp rating, max : 1Hp @ 575V, 3-phase KW rating, max : 1.1 kW @ 690V (AC-3), 3-phase Magnetic release current : Fixed setting 13.14 x Ie max. Ie max. = maximum values of setting ranges, (±20 %) Magnetic trip current : 21 A Main circuits/overvoltage category : 6kV/III @ rated impulse withstand voltage (Uimp) Number of poles : 3 Phase failure sensitive : true Phase loss protection : Differential release Rated frequency : 50/60 Hz Rated operating voltage : 230 A Rated operating voltage, max : 690V per IEC, SEV, VDE0660 Rated supply current : 0.1 A Rated thermal current : 0.1.32A @ 60°C ambient temperature (Ith)-inv Switching frequency, max : 25 ops/h Switch off technique : Thermomagnetic Trip class : 10 Type of control element : Turn button With thermal protection : true Construction
Contactor size, min-inv : 100-K05: UL-508-Type F combination motor controller Device construction : Built-in device fixed built-in technique Frame size : Frame size C, 32 A Mechanical
Breaking capacity : Standard breaking capacity Factory option : No circuit-breaker auxiliary or trip contacts Mechanical life operations : 100000 /h Protection type : Adjustable thermal/fixed magnetic (13 x In) Shock resistance : Transport (60068-2-27): 30 G, 11 ms, all axes Terminal type : Screw connection Vibration resistance : ops (60068-2-6): 5 G Weight : 317 lb Standards Protection
Ambient operating temperature : -25 °C Ambient storage temperature : -40 °C Ambient temperature compensation : -20 °C Dependence on temperature : No current reduction @ 60 °C-inv Dry heat : 100 °C, relative humidity < 50 %, 7 d (60086-2-2)-inv Moisture change climate : 23 °C/83 % relative humidity and 40 °C/92 % relative humidity, 56 cycles (600068-2-30)-inv Moisture heat : 40 °C, relative humidity 93 %, 56 d (60068-2-3)-inv Pollution degree : 3 Site altitude : To 2000 N.N.(m) Overview
Standard Warranty Duration : 1 year Specifications
Build America, Buy America : No Repair Options Available : No Degree of protection : IP2X Depth : 74.5 mm Height : 90 mm Width : 45 mm Country of Origin : Switzerland - Downloads
Spec Sheet