Product Description:
140MP Motor Protection Circuit Breaker / Manual Motor Starter, Frame Size A, 5 kA, Adjustable Thermal/Fixed Magnetic MPCB, 1.6 - 2.5A
HESCO Part Number
AB140MPA3EB25
UPC
191326954471
Manufacturer Part Number
140MP-A3E-B25
Manufacturer
Allen-Bradley
Motor Protection Circuit Breaker (140MP-A3E-B25)
MFG #140MP-A3E-B25
Product Description:
140MP Motor Protection Circuit Breaker / Manual Motor Starter, Frame Size A, 5 kA, Adjustable Thermal/Fixed Magnetic MPCB, 1.6 - 2.5A
HESCO Part Number
AB140MPA3EB25
UPC
191326954471
Manufacturer Part Number
140MP-A3E-B25
Manufacturer
Allen-Bradley
$288.13 / E
EACH
EACH
- Features
- Specifications
- Resources
- IECEE Scheme
- 2000 m altitude
- UL Listed
- Housing: IP20, Main terminals: IP10
- China CCC
- Built-in device fixed built-in technique
- Up to 40 °C (104 °F) group mounting side by side
- 2Hp @ 575V, 3-phase hp rating, max
- Rated 690V insulation voltage
- AC-3: 1.8 kW @ 690V, 3-phase
- 31.3 A
Power Electrical Characteristics
| Hp rating, max | : | 2Hp @ 575V, 3-phase |
| KW rating, max | : | AC-3: 1.8 kW @ 690V, 3-phase |
| Magnetic trip current | : | 31.3 A |
| Max current Ie | : | 32 A |
| Motor current adjustment range | : | 1.6.2.5 A |
| Number of operations | : | Mechanical: 100.000 cycles, Electrical: 100000 cycles (0.1.16 A), 50000 cycles (20.32 A) |
| Number of poles | : | 3 |
| Phase failure sensitive | : | true |
| Power loss | : | 5.1 W @ 0.16.1.6 rated operating current, 5.4 @ 2.5.6.3 rated operating current, 7.2 @ 10.12 rated operating current, 8.4 @ 16.25 rated operating current, 9.3 @ 32 rated operating current |
| Rated frequency | : | 50/60 Hz |
| Rated operating voltage | : | 0 A |
| Short circuit current Icu, max | : | 75kA @ 400V |
| Short circuit current, max | : | Type 2 coordination, IEC 60947-4-1: 50kA @ 400V |
| Short circuit current rating | : | Type 1 coordination: 5kA @ 600V AC |
| Trip class | : | 10 A |
| Type of control element | : | Turn button |
| With thermal protection | : | true |
Construction | ||
| Device construction | : | Built-in device fixed built-in technique |
| Group mounting side by side | : | Up to 40 °C (104 °F) |
| Mounting | : | DIN Rail (EN 60715) |
Mechanical | ||
| Degree of protection | : | Housing: IP20, Main terminals: IP10 |
| Resistance to shock | : | 25 G/11 ms per IEC 60068-2-27 |
| Resistance to vibration | : | 5 G/3 . 150 Hz per IEC 60068-2-6 |
Standards Protection | ||
| Altitude | : | 2000 m |
| Pollution degree | : | 3 |
Overview | ||
| Standard Warranty Duration | : | 1 year |
Specifications | ||
| Build America, Buy America | : | No |
| Repair Options Available | : | No |
| Insulation voltage | : | Rated 690V |
| Maximum operating voltage | : | 600 V |
| Rated operational current | : | 2.5 A |
| Country of Origin | : | Germany |
- IECEE Scheme
- 2000 m altitude
- UL Listed
- Housing: IP20, Main terminals: IP10
- China CCC
- Built-in device fixed built-in technique
- Up to 40 °C (104 °F) group mounting side by side
- 2Hp @ 575V, 3-phase hp rating, max
- Rated 690V insulation voltage
- AC-3: 1.8 kW @ 690V, 3-phase
- 31.3 A
Power Electrical Characteristics
Hp rating, max : 2Hp @ 575V, 3-phase KW rating, max : AC-3: 1.8 kW @ 690V, 3-phase Magnetic trip current : 31.3 A Max current Ie : 32 A Motor current adjustment range : 1.6.2.5 A Number of operations : Mechanical: 100.000 cycles, Electrical: 100000 cycles (0.1.16 A), 50000 cycles (20.32 A) Number of poles : 3 Phase failure sensitive : true Power loss : 5.1 W @ 0.16.1.6 rated operating current, 5.4 @ 2.5.6.3 rated operating current, 7.2 @ 10.12 rated operating current, 8.4 @ 16.25 rated operating current, 9.3 @ 32 rated operating current Rated frequency : 50/60 Hz Rated operating voltage : 0 A Short circuit current Icu, max : 75kA @ 400V Short circuit current, max : Type 2 coordination, IEC 60947-4-1: 50kA @ 400V Short circuit current rating : Type 1 coordination: 5kA @ 600V AC Trip class : 10 A Type of control element : Turn button With thermal protection : true Construction
Device construction : Built-in device fixed built-in technique Group mounting side by side : Up to 40 °C (104 °F) Mounting : DIN Rail (EN 60715) Mechanical
Degree of protection : Housing: IP20, Main terminals: IP10 Resistance to shock : 25 G/11 ms per IEC 60068-2-27 Resistance to vibration : 5 G/3 . 150 Hz per IEC 60068-2-6 Standards Protection
Altitude : 2000 m Pollution degree : 3 Overview
Standard Warranty Duration : 1 year Specifications
Build America, Buy America : No Repair Options Available : No Insulation voltage : Rated 690V Maximum operating voltage : 600 V Rated operational current : 2.5 A Country of Origin : Germany - Downloads
Data Sheet