Allen-Bradley
Speed Measurement Module
MFG #1440-SPD02-01RB
$4,230.92 / E
EACH
EACH
Product Description:
1440-SPD02-01RB: XM-220 Dual Speed Module
HESCO Part Number
AB1440SPD0201RB
UPC
781180505355
Manufacturer Part Number
1440-SPD02-01RB
Manufacturer
Allen-Bradley
Allen-Bradley
Speed Measurement Module
MFG #1440-SPD02-01RB
Product Description:
1440-SPD02-01RB: XM-220 Dual Speed Module
HESCO Part Number
AB1440SPD0201RB
UPC
781180505355
Manufacturer Part Number
1440-SPD02-01RB
Manufacturer
Allen-Bradley
$4,230.92 / E
EACH
EACH
- Features
- Specifications
- Resources
- China CCC
- 2 output
- UKCA DOC
- 2 tachometer inputs
- ATEX
- Alarm and danger pair that is provided for each of: Speed, Acceleration, Zero speed, Locked rotor
- Output range configurable by wiring, -24.9V, -5…24V, -5…9V, Third buffered outpit available when the module is configured for single redundant channel mode, Outputs a CMOS (0…5V) level square-wave that corresponds to the active input signal
- 10V rms with 1 kHz sine-wave 80% AM from 150 kHz.80 MHz
- All printed circuit boards are conformally coated in accordance with IPC-A-610C
General Features
| Output | : | 2 |
| Tachometer Inputs | : | 2 |
| Nonvolatile configuration | : | A copy of the module configuration is retained in nonvolatile memory from which the configuration is loaded upon powerup, The configuration that is stored in nonvolatile memory can be deleted only by a module-reset,command that is sent via a serial interf |
| Status indicator | : | Module - red/green, Network - red/green, Channel 1 - yellow/red, Channel 2 - yellow/red, Startup - yellow, Relay - red, AUX - reserved for future use |
Inputs Outputs Io | ||
| 4...20 mA outputs | : | Each output is independently progmed to represent speed or acceleration, from either channel, Two isolated outputs, 300Ω max load, One active buffer per input channel |
| Buffered outputs | : | Output range configurable by wiring, -24.9V, -5…24V, -5…9V, Third buffered outpit available when the module is configured for single redundant channel mode, Outputs a CMOS (0…5V) level square-wave that corresponds to the active input signal |
| Input impedance | : | 120 kΩ minimum |
| Speed measurement error | : | 1…240 rpm: ±0.2 rpm, 241…12,000 rpm: ±2 rpm, 12,001…20,400 rpm: ±5 rpm, 20,401…120,000 rpm: ±20 rpm, 120,001…360,000 rpm: ±50 rpm, 360,001…1,200,000 rpm: ±160 rpm |
| Speed range | : | 1 r/m |
| Two tachometer inputs | : | ±25V (50V max peak-to-peak), Eddy current transducer signals, Magnetic pickups, TTL output devices |
Power Electrical Characteristics | ||
| Consumption | : | 300 mA, max, 225 mA, typical |
| Heat production | : | 7 W (24 BTU/hr), max, 4 W (14 BTU/hr), typical |
| Isolation voltage | : | 250V (continuous), Basic Insulation Type, relay to all other circuits, Isolation between other circuits is not rated, Type tested at 1500V AC @ 60s |
| Module | : | 24V DC |
| Power dissipation, max | : | 7 W |
| Rated operating frequency | : | 0.0167 khz |
| Transducer | : | Isolated 24V DC, user configurable with wiring |
| Type of electric connection | : | Screw connection |
| Voltage and current ratings | : | Supply: 24V DC @ 0.3A max, Class 2/SELV, Relay: 120V AC @ 0.5A, 110V DC @ 0.5A, 30V DC @ 1.0A |
| Voltage type for actuating | : | DC |
| Wire type | : | Signal connections: shielded, Power and relay connections: unshielded |
| Wiring category | : | 2 - on relay and signal ports, 3 - on serial and power ports, 2 - on XM bus ports |
Communication Interfaces | ||
| DeviceNet network | : | Standard DeviceNet protocol for all functions (not power-module power is provided independently), Available EDS file supports most DeviceNet compliant systems, Communication rate that is set automatically by bus master to 125 Kbps, 250 Kbps, or 500 Kbps, |
| Serial | : | RS-232 via mini-connector or terminal base unit, Communication rate that is fixed at 19.2 Kbps, Local configuration via the Serial Configuration Utility |
Measurement Parameters | ||
| Dual channel | : | Two sensors are used independently to perform two separate speed, acceleration and peak speed measurements |
| Measured parameters | : | Forward, Reverse, Rpm, Direction of rotation, Acceleration in Rpm/min |
| Peak speed capture | : | The module retains the value of the highest speed that is observed since module power was cycled or the peak speed value was manually reset |
| Reverse rotation | : | Two sensors are used to monitor both speed and direction. The two sensors must be mounted out of phase from each other so that the rotational direction can be determined by monitoring which sensor the shaft keyway passes first |
| Single redundant channel | : | One sensor is used to perform the speed, acceleration, and peak speed measurements. If the current sensor fails, the module automatically switches to the s (redundant) sensor |
| Units | : | Rpm, Direction of rotation, Acceleration in rpm/min |
Construction | ||
| Enclosure type rating | : | None (open-style) |
Mechanical | ||
| Shock | : | opsal: 15 G |
| Vibration | : | 2.0 G @ 10…500 Hz |
Relays Control Outputs | ||
| Activation on | : | Alarm Status: Normal, Alert, Danger, Disarm, Transducer fault, Module fault, Tacho fault |
| Failsafe | : | Normally energized (fail-safe), Normally de-energized (non-failsafe) |
| Latching | : | Latching, non-latching |
| Logic | : | Single or paired AND or OR logic that is applied to any alarm |
| Number | : | Single on-board relay, two sets of contacts - DPDT (two Form C), Four additional relays when interconnected to an XM-441 expansion relay module, or, Four virtual relays whose status can be used by remote control systems or the XM-440 master relay module |
| On-board relay rating | : | Voltage, max: 120V DC @ 125V AC, Current: 0…3.5 A, Power, max: 60 W, 62.5VA, max currentis up to 40 °C (104 °F), then derates to 2A @ 65°C (149 °F), Agency rating, 120V AC @ 0.5A, 110V DC @ 0.3A, 30V DC @ 1.0A |
| Reset | : | Local reset switch on top of module, Remote reset switch that is wired to terminal base, Digital reset command via serial or DeviceNet interface |
| Time delay | : | 0…25.5 s, adjustable in 100 ms increments |
Alarms Fault Management | ||
| Alarm parameters | : | Alarm and danger pair that is provided for each of: Speed, Acceleration, Zero speed, Locked rotor |
| Eddy current transducer | : | Bias voltage is compared with the fault limits |
| Hysteresis | : | User configurable in software |
| Operator | : | Greater than, Less than, Inside range, Outside range |
Standards Protection | ||
| Conducted RF immunity | : | 10V rms with 1 kHz sine-wave 80% AM from 150 kHz.80 MHz |
| Conformal coating | : | All printed circuit boards are conformally coated in accordance with IPC-A-610C |
| EFT/B immunity | : | ±2kV @ 5kHz on power ports, ±1kV @ 5kHz on relay and signal ports, ±1kV @ 5kHz on XM bus port |
| Emissions | : | Class A |
| ESD immunity | : | 6 kV contact discharges, 8 kV air discharges |
| Nonoperating temperature | : | -40 °C |
| Operating temperature | : | -20 °C |
| Radiated RF immunity | : | 10 V/m with 1 kHz sine-wave 80% AM from 80.2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000.2700 MHz |
| Relative humidity | : | 5.95% noncondensing |
| Storage temperature | : | -40 °C |
| Surge transient immunity | : | ±2 kV line-earth(CM) on relay and shielded signal ports, ±2 kV line-earth(CM) on XM bus port |
Overview | ||
| Standard Warranty Duration | : | 1 year |
Specifications | ||
| 4...20 mA outputs | : | Each output is independently progmed to represent speed or acceleration, from either channel, Two isolated outputs, 300Ω max load, One active buffer per input channel |
| Alarm Status | : | Normal, Alert, Danger, Disarm, Transducer fault, Module fault, Tacho fault |
| Build America, Buy America | : | No |
| Repair Options Available | : | Yes |
| Depth | : | 94 mm |
| Height | : | 97 mm |
| Width | : | 94 mm |
| Country of Origin | : | United States |
- China CCC
- 2 output
- UKCA DOC
- 2 tachometer inputs
- ATEX
- Alarm and danger pair that is provided for each of: Speed, Acceleration, Zero speed, Locked rotor
- Output range configurable by wiring, -24.9V, -5…24V, -5…9V, Third buffered outpit available when the module is configured for single redundant channel mode, Outputs a CMOS (0…5V) level square-wave that corresponds to the active input signal
- 10V rms with 1 kHz sine-wave 80% AM from 150 kHz.80 MHz
- All printed circuit boards are conformally coated in accordance with IPC-A-610C
General Features
Output : 2 Tachometer Inputs : 2 Nonvolatile configuration : A copy of the module configuration is retained in nonvolatile memory from which the configuration is loaded upon powerup, The configuration that is stored in nonvolatile memory can be deleted only by a module-reset,command that is sent via a serial interf Status indicator : Module - red/green, Network - red/green, Channel 1 - yellow/red, Channel 2 - yellow/red, Startup - yellow, Relay - red, AUX - reserved for future use Inputs Outputs Io
4...20 mA outputs : Each output is independently progmed to represent speed or acceleration, from either channel, Two isolated outputs, 300Ω max load, One active buffer per input channel Buffered outputs : Output range configurable by wiring, -24.9V, -5…24V, -5…9V, Third buffered outpit available when the module is configured for single redundant channel mode, Outputs a CMOS (0…5V) level square-wave that corresponds to the active input signal Input impedance : 120 kΩ minimum Speed measurement error : 1…240 rpm: ±0.2 rpm, 241…12,000 rpm: ±2 rpm, 12,001…20,400 rpm: ±5 rpm, 20,401…120,000 rpm: ±20 rpm, 120,001…360,000 rpm: ±50 rpm, 360,001…1,200,000 rpm: ±160 rpm Speed range : 1 r/m Two tachometer inputs : ±25V (50V max peak-to-peak), Eddy current transducer signals, Magnetic pickups, TTL output devices Power Electrical Characteristics
Consumption : 300 mA, max, 225 mA, typical Heat production : 7 W (24 BTU/hr), max, 4 W (14 BTU/hr), typical Isolation voltage : 250V (continuous), Basic Insulation Type, relay to all other circuits, Isolation between other circuits is not rated, Type tested at 1500V AC @ 60s Module : 24V DC Power dissipation, max : 7 W Rated operating frequency : 0.0167 khz Transducer : Isolated 24V DC, user configurable with wiring Type of electric connection : Screw connection Voltage and current ratings : Supply: 24V DC @ 0.3A max, Class 2/SELV, Relay: 120V AC @ 0.5A, 110V DC @ 0.5A, 30V DC @ 1.0A Voltage type for actuating : DC Wire type : Signal connections: shielded, Power and relay connections: unshielded Wiring category : 2 - on relay and signal ports, 3 - on serial and power ports, 2 - on XM bus ports Communication Interfaces
DeviceNet network : Standard DeviceNet protocol for all functions (not power-module power is provided independently), Available EDS file supports most DeviceNet compliant systems, Communication rate that is set automatically by bus master to 125 Kbps, 250 Kbps, or 500 Kbps, Serial : RS-232 via mini-connector or terminal base unit, Communication rate that is fixed at 19.2 Kbps, Local configuration via the Serial Configuration Utility Measurement Parameters
Dual channel : Two sensors are used independently to perform two separate speed, acceleration and peak speed measurements Measured parameters : Forward, Reverse, Rpm, Direction of rotation, Acceleration in Rpm/min Peak speed capture : The module retains the value of the highest speed that is observed since module power was cycled or the peak speed value was manually reset Reverse rotation : Two sensors are used to monitor both speed and direction. The two sensors must be mounted out of phase from each other so that the rotational direction can be determined by monitoring which sensor the shaft keyway passes first Single redundant channel : One sensor is used to perform the speed, acceleration, and peak speed measurements. If the current sensor fails, the module automatically switches to the s (redundant) sensor Units : Rpm, Direction of rotation, Acceleration in rpm/min Construction
Enclosure type rating : None (open-style) Mechanical
Shock : opsal: 15 G Vibration : 2.0 G @ 10…500 Hz Relays Control Outputs
Activation on : Alarm Status: Normal, Alert, Danger, Disarm, Transducer fault, Module fault, Tacho fault Failsafe : Normally energized (fail-safe), Normally de-energized (non-failsafe) Latching : Latching, non-latching Logic : Single or paired AND or OR logic that is applied to any alarm Number : Single on-board relay, two sets of contacts - DPDT (two Form C), Four additional relays when interconnected to an XM-441 expansion relay module, or, Four virtual relays whose status can be used by remote control systems or the XM-440 master relay module On-board relay rating : Voltage, max: 120V DC @ 125V AC, Current: 0…3.5 A, Power, max: 60 W, 62.5VA, max currentis up to 40 °C (104 °F), then derates to 2A @ 65°C (149 °F), Agency rating, 120V AC @ 0.5A, 110V DC @ 0.3A, 30V DC @ 1.0A Reset : Local reset switch on top of module, Remote reset switch that is wired to terminal base, Digital reset command via serial or DeviceNet interface Time delay : 0…25.5 s, adjustable in 100 ms increments Alarms Fault Management
Alarm parameters : Alarm and danger pair that is provided for each of: Speed, Acceleration, Zero speed, Locked rotor Eddy current transducer : Bias voltage is compared with the fault limits Hysteresis : User configurable in software Operator : Greater than, Less than, Inside range, Outside range Standards Protection
Conducted RF immunity : 10V rms with 1 kHz sine-wave 80% AM from 150 kHz.80 MHz Conformal coating : All printed circuit boards are conformally coated in accordance with IPC-A-610C EFT/B immunity : ±2kV @ 5kHz on power ports, ±1kV @ 5kHz on relay and signal ports, ±1kV @ 5kHz on XM bus port Emissions : Class A ESD immunity : 6 kV contact discharges, 8 kV air discharges Nonoperating temperature : -40 °C Operating temperature : -20 °C Radiated RF immunity : 10 V/m with 1 kHz sine-wave 80% AM from 80.2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000.2700 MHz Relative humidity : 5.95% noncondensing Storage temperature : -40 °C Surge transient immunity : ±2 kV line-earth(CM) on relay and shielded signal ports, ±2 kV line-earth(CM) on XM bus port Overview
Standard Warranty Duration : 1 year Specifications
4...20 mA outputs : Each output is independently progmed to represent speed or acceleration, from either channel, Two isolated outputs, 300Ω max load, One active buffer per input channel Alarm Status : Normal, Alert, Danger, Disarm, Transducer fault, Module fault, Tacho fault Build America, Buy America : No Repair Options Available : Yes Depth : 94 mm Height : 97 mm Width : 94 mm Country of Origin : United States - Downloads
Spec Sheet