PowerFlex 70 AC Drive 11 A at 7.5 Hp 20A (20AD011C3AYNANC0)
MFG #20AD011C3AYNANC0
$5,483.81 / E
EACH
EACH
Product Description:
PowerFlex70 AC Drive, 480 VAC, 3 PH, 11 Amps, 7.5 HP Normal Duty, 5 HP Heavy Duty,Wall / Machine Mount - IP66/NEMA Type 4X/12 (Indoor Use), with conformal coating, LCD Display, Full Numeric Keypad, Brake IGBT Installed, Without Drive Mounted Brake Resistor, Second Environment Filter per CE EMC directive (89/336/EEC), No Communication Module, Enhanced Control , No Feedback
HESCO Part Number
AB20AD011C3AYNANC0
UPC
820919373800
Manufacturer Part Number
20AD011C3AYNANC0
Manufacturer
Allen-Bradley
PowerFlex 70 AC Drive 11 A at 7.5 Hp 20A (20AD011C3AYNANC0)
MFG #20AD011C3AYNANC0
Product Description:
PowerFlex70 AC Drive, 480 VAC, 3 PH, 11 Amps, 7.5 HP Normal Duty, 5 HP Heavy Duty,Wall / Machine Mount - IP66/NEMA Type 4X/12 (Indoor Use), with conformal coating, LCD Display, Full Numeric Keypad, Brake IGBT Installed, Without Drive Mounted Brake Resistor, Second Environment Filter per CE EMC directive (89/336/EEC), No Communication Module, Enhanced Control , No Feedback
HESCO Part Number
AB20AD011C3AYNANC0
UPC
820919373800
Manufacturer Part Number
20AD011C3AYNANC0
Manufacturer
Allen-Bradley
$5,483.81 / E
EACH
EACH
- Features
- Specifications
- Resources
- Eurasion Economic Community
- Brake IGBT Installed
- Korean KC
- No Internal brake resistor
- Australian RCM
- Enhanced Control with 24V I/O
- UL Listed
- No Communication Module internal communication module
- Two independently progmable accel and decel times. Each time can be progmed from 0.3600 s in 0.1 s increments
- 570V AC @ 480V ac input overvoltage trip
- 280V AC @ 480V ac input undervoltage trip
- 1000 m (3300 ft.) maximum without derating
General Features
| Brake IGBT | : | Brake IGBT Installed |
| Brake Resistor | : | No Internal |
| Control | : | Enhanced Control with 24V I/O |
| Internal Communication Module | : | No Communication Module |
Power Electrical Characteristics | ||
| Acceleration/deceleration | : | Two independently progmable accel and decel times. Each time can be progmed from 0.3600 s in 0.1 s increments |
| AC input overvoltage trip | : | 570V AC @ 480V |
| AC input undervoltage trip | : | 280V AC @ 480V |
| Bus overvoltage trip | : | 810V DC @ 480V |
| Bus undervoltage fault level | : | 300V DC @ 480V |
| Bus voltage, nom | : | 648V DC @ 480V |
| Carrier frequency | : | Standard control: 2, 3, 4, 5, 6, 7, 8, 9, and 10 kHz, vector control: 2, 4, 8, and 12 kHz, drive rating based on 4 kHz |
| Control logic noise immunity | : | Showering arc transients upto 1500V peak |
| Control method | : | Sine coded PWM with progmable carrier frequency. Ratings apply to all drives |
| Control options | : | Enhanced control with 24V I/O |
| Cooling fan operation | : | Frames B, D, and E: fan operates when power is applied and in run condition |
| Current limit capability | : | Proactive current limit progmable from 20.160% of rated output current, Independently progmable proportional and integral gain |
| Documentation | : | Manual |
| Drive overcurrent trip | : | Software current limit: 20.160% of rated current |
| Efficiency | : | 97.5% at rated A, nominal line volts |
| Enclosure type | : | Wall/machine mount-IP66/NEMA Type 4X/12 (indoor use) |
| Encoder duty cycle | : | 50% ±10% |
| Encoder quadrature | : | 90° ±27° |
| Encoder supply | : | 5V/12V configurable ±5% |
| Encoder type | : | Incremental, dual channel |
| External watts loss | : | 140.0 W @ 480V @ 7.5Hp normal duty |
| Feedback option | : | No ftdback |
| Frequency accuracy | : | Digital input: within ±0.01% of set output frequency |
| Frequency control-speed regulation | : | With slip compensation (Volts per Hz mode): 0.5% of base speed across 40:1 speed range, 40:1 operating range, 10 rad/sec bandwidth |
| Ground fault trip | : | Phase-to-ground on drive output |
| Heat sink thermistor | : | Monitored by microprocessor overtemp trip |
| Human interface model | : | LCD display, full numeric keypad |
| Input current rating | : | 9.5A @ 480V AC, 1-phase |
| Input frequency tolerance | : | 47 Hz |
| Input phases | : | Three-phase input provides full rating for all drives. single-phase ops provides 50% of rated current |
| Input power rating | : | 7.9 kVA @ 480V AC, 3-phase |
| Integrated breaking resistance | : | false |
| Intermittent overload | : | 110% overload capability for up to 1 min, 150% overload capability for up to 3 s |
| Internal EMC filtering | : | s environment filter per CE EMC directive (89/336/EEC) |
| Internal watts loss | : | 27.8 W @ 480V @ 7.5Hp normal duty |
| Line transients | : | Up to 6000 volts peak per IEEE C62.41-1991 |
| Logic control ride-thru | : | 0.5 s minimum, 2 s typical |
| Mains frequency | : | 50 Hz |
| Mains voltage | : | 480 V |
| Motor overload protection | : | Class 10 motor overload protection according to NEC article 430 and motor over-temperature protection according to NEC article 430.126 (A)(2). UL 508C file E59272 |
| Number of analogue inputs | : | 2 |
| Number of analogue outputs | : | 1 |
| Number of digital inputs | : | 6 |
| Number of digital outputs | : | 2 |
| Number of HW-interfaces RS-232 | : | 2 |
| Number of HW-interfaces RS-485 | : | 2 |
| Number of HW-interfaces USB | : | 2 |
| Number of phases input | : | 3 |
| Number of phases output | : | 3 |
| Output current rating, 1 min | : | 6.1A @ 480V AC, 1-phase |
| Output current rating, 3 sec | : | 8.3A @ 480V AC, 1-phase |
| Output current rating | : | 11 A, 7.5 Hp normal duty, 5 Hp heavy duty, frame C |
| Output frequency range | : | Standard control: 0.400 Hz, enhanced control: 0.500 Hz |
| Output voltage range | : | 0 to rated motor voltage |
| Power ride-thru | : | 15 ms at full load |
| Selectable motor control | : | Sensorless vector with full tuning. Standards V/Hz with full custom capability and vector control |
| Short circuit rating, max | : | 200000 A symmetrical |
| Short circuit trip | : | Phase-to-phase on drive output |
| Speed control-speed regulation | : | Without ftdback (Vector Control mode): 0.1% of base speed across 120:1 speed range, 120:1 operating range, 30 rad/sec bandwidth |
| Stop modes | : | Multiple progmable stop modes including - RA, Coast, DC-brake, Fast brake, RA-to-hold and S-curve |
| Supporting protocol for CAN | : | true |
| Supporting protocol for Modbus | : | true |
| Supporting protocol for TCP/IP | : | true |
| Torque regulation | : | Without ftdback +/-10%, with ftdback +/-5% |
| Total watts loss | : | 167.8 W @ 480V @ 7.5Hp normal duty |
| Voltage tolerance | : | -10 % |
| With control element | : | true |
Construction | ||
| Depth, approx | : | IP20, NEMA/UL Type 1: 179.8 mm |
| Height, approx | : | IP20, NEMA/UL Type 1: 300 mm |
| Weight, approx | : | IP20, NEMA/UL Type 1: 6.89 kg |
| Width, approx | : | IP20, NEMA/UL Type 1: 185 mm |
Mechanical | ||
| Shock | : | 15 G peak for 11 ms duration (±1.0 ms) |
| Vibration | : | 0.152 mm (0.006 in) displacement, 1 G peak |
Standards Protection | ||
| Altitude | : | 1000 m (3300 ft.) maximum without derating |
| Atmosphere | : | Drive must not be installed in an area where the ambient atmosphere contains volatile or corrosive gas, vapors or dust, If the drive is not going to be installed immediately, store the drive where it is not exposed to a corrosive atmosphere |
| Relative humidity | : | 5.95% noncondensing |
| Storage temperature | : | -40 °C |
Overview | ||
| Standard Warranty Duration | : | 1 year |
Specifications | ||
| Build America, Buy America | : | No |
| Repair Options Available | : | Yes |
| Degree of protection | : | IP66 |
| Displacement power factor | : | 0.98 across speed range |
| Country of Origin | : | Mexico |
- Eurasion Economic Community
- Brake IGBT Installed
- Korean KC
- No Internal brake resistor
- Australian RCM
- Enhanced Control with 24V I/O
- UL Listed
- No Communication Module internal communication module
- Two independently progmable accel and decel times. Each time can be progmed from 0.3600 s in 0.1 s increments
- 570V AC @ 480V ac input overvoltage trip
- 280V AC @ 480V ac input undervoltage trip
- 1000 m (3300 ft.) maximum without derating
General Features
Brake IGBT : Brake IGBT Installed Brake Resistor : No Internal Control : Enhanced Control with 24V I/O Internal Communication Module : No Communication Module Power Electrical Characteristics
Acceleration/deceleration : Two independently progmable accel and decel times. Each time can be progmed from 0.3600 s in 0.1 s increments AC input overvoltage trip : 570V AC @ 480V AC input undervoltage trip : 280V AC @ 480V Bus overvoltage trip : 810V DC @ 480V Bus undervoltage fault level : 300V DC @ 480V Bus voltage, nom : 648V DC @ 480V Carrier frequency : Standard control: 2, 3, 4, 5, 6, 7, 8, 9, and 10 kHz, vector control: 2, 4, 8, and 12 kHz, drive rating based on 4 kHz Control logic noise immunity : Showering arc transients upto 1500V peak Control method : Sine coded PWM with progmable carrier frequency. Ratings apply to all drives Control options : Enhanced control with 24V I/O Cooling fan operation : Frames B, D, and E: fan operates when power is applied and in run condition Current limit capability : Proactive current limit progmable from 20.160% of rated output current, Independently progmable proportional and integral gain Documentation : Manual Drive overcurrent trip : Software current limit: 20.160% of rated current Efficiency : 97.5% at rated A, nominal line volts Enclosure type : Wall/machine mount-IP66/NEMA Type 4X/12 (indoor use) Encoder duty cycle : 50% ±10% Encoder quadrature : 90° ±27° Encoder supply : 5V/12V configurable ±5% Encoder type : Incremental, dual channel External watts loss : 140.0 W @ 480V @ 7.5Hp normal duty Feedback option : No ftdback Frequency accuracy : Digital input: within ±0.01% of set output frequency Frequency control-speed regulation : With slip compensation (Volts per Hz mode): 0.5% of base speed across 40:1 speed range, 40:1 operating range, 10 rad/sec bandwidth Ground fault trip : Phase-to-ground on drive output Heat sink thermistor : Monitored by microprocessor overtemp trip Human interface model : LCD display, full numeric keypad Input current rating : 9.5A @ 480V AC, 1-phase Input frequency tolerance : 47 Hz Input phases : Three-phase input provides full rating for all drives. single-phase ops provides 50% of rated current Input power rating : 7.9 kVA @ 480V AC, 3-phase Integrated breaking resistance : false Intermittent overload : 110% overload capability for up to 1 min, 150% overload capability for up to 3 s Internal EMC filtering : s environment filter per CE EMC directive (89/336/EEC) Internal watts loss : 27.8 W @ 480V @ 7.5Hp normal duty Line transients : Up to 6000 volts peak per IEEE C62.41-1991 Logic control ride-thru : 0.5 s minimum, 2 s typical Mains frequency : 50 Hz Mains voltage : 480 V Motor overload protection : Class 10 motor overload protection according to NEC article 430 and motor over-temperature protection according to NEC article 430.126 (A)(2). UL 508C file E59272 Number of analogue inputs : 2 Number of analogue outputs : 1 Number of digital inputs : 6 Number of digital outputs : 2 Number of HW-interfaces RS-232 : 2 Number of HW-interfaces RS-485 : 2 Number of HW-interfaces USB : 2 Number of phases input : 3 Number of phases output : 3 Output current rating, 1 min : 6.1A @ 480V AC, 1-phase Output current rating, 3 sec : 8.3A @ 480V AC, 1-phase Output current rating : 11 A, 7.5 Hp normal duty, 5 Hp heavy duty, frame C Output frequency range : Standard control: 0.400 Hz, enhanced control: 0.500 Hz Output voltage range : 0 to rated motor voltage Power ride-thru : 15 ms at full load Selectable motor control : Sensorless vector with full tuning. Standards V/Hz with full custom capability and vector control Short circuit rating, max : 200000 A symmetrical Short circuit trip : Phase-to-phase on drive output Speed control-speed regulation : Without ftdback (Vector Control mode): 0.1% of base speed across 120:1 speed range, 120:1 operating range, 30 rad/sec bandwidth Stop modes : Multiple progmable stop modes including - RA, Coast, DC-brake, Fast brake, RA-to-hold and S-curve Supporting protocol for CAN : true Supporting protocol for Modbus : true Supporting protocol for TCP/IP : true Torque regulation : Without ftdback +/-10%, with ftdback +/-5% Total watts loss : 167.8 W @ 480V @ 7.5Hp normal duty Voltage tolerance : -10 % With control element : true Construction
Depth, approx : IP20, NEMA/UL Type 1: 179.8 mm Height, approx : IP20, NEMA/UL Type 1: 300 mm Weight, approx : IP20, NEMA/UL Type 1: 6.89 kg Width, approx : IP20, NEMA/UL Type 1: 185 mm Mechanical
Shock : 15 G peak for 11 ms duration (±1.0 ms) Vibration : 0.152 mm (0.006 in) displacement, 1 G peak Standards Protection
Altitude : 1000 m (3300 ft.) maximum without derating Atmosphere : Drive must not be installed in an area where the ambient atmosphere contains volatile or corrosive gas, vapors or dust, If the drive is not going to be installed immediately, store the drive where it is not exposed to a corrosive atmosphere Relative humidity : 5.95% noncondensing Storage temperature : -40 °C Overview
Standard Warranty Duration : 1 year Specifications
Build America, Buy America : No Repair Options Available : Yes Degree of protection : IP66 Displacement power factor : 0.98 across speed range Country of Origin : Mexico - Downloads
Spec Sheet
Application Technique
Data Sheet
Reference Manual 1
Product Profile
General 1
Brochure
Dimension/Usage Sheet
General 2
General 3
General 4
Installation Instructions
Quick Reference
Reference Manual 2
User Manual 2
Wiring Diagram