NEMA Size 0 Contactor (300-AOEJ9310)
MFG #300-AOEJ9310
$738.89 / E
EACH
EACH
Product Description:
300 NEMA Contactor, Size 0, 24-60V 50-60 Hz/20-60V DC Low Consumption, 3 NO Poles, 0 NO, 0 NC Auxiliary Contact, Screw Terminals
HESCO Part Number
AB300AOEJ9310
UPC
191326935630
Manufacturer Part Number
300-AOEJ9310
Manufacturer
Allen-Bradley
NEMA Size 0 Contactor (300-AOEJ9310)
MFG #300-AOEJ9310
Product Description:
300 NEMA Contactor, Size 0, 24-60V 50-60 Hz/20-60V DC Low Consumption, 3 NO Poles, 0 NO, 0 NC Auxiliary Contact, Screw Terminals
HESCO Part Number
AB300AOEJ9310
UPC
191326935630
Manufacturer Part Number
300-AOEJ9310
Manufacturer
Allen-Bradley
$738.89 / E
EACH
EACH
- Features
- Specifications
- Resources
- China CCC
- 2000 m of installation site altitude, max
- UL Listed
- 65,000A @ 480V max, circuit breaker, RMS symmetrical
- Eurasion Economic Community
- Category B according to IEC 60947-1, annex Q
- Australian RCM
- Electronic coil
- Korean KC
- 30.60% x voltage @ 50/60 Hz
- UKCA DOC
- 85.10% x voltage @ 50/60 Hz
- Sizes 0.3: 3 power poles with internal N.O. or N.C. auxiliary contact or 4 power poles., Sizes 1.3: 3 power poles with side mounted N.O. / N.C. auxiliary contact or 4 power poles, Sizes 4.8: 3 main poles with 2 auxiliary contacts (1 N.O. and 1 N.C.)
Power Electrical Characteristics
| Available short circuit ampere | : | 65,000A @ 480V max, circuit breaker, RMS symmetrical |
| Coil | : | Electronic |
| Coil operating limits, dropout | : | 30.60% x voltage @ 50/60 Hz |
| Coil operating limits, pick-up | : | 85.10% x voltage @ 50/60 Hz |
| Contacts | : | Sizes 0.3: 3 power poles with internal N.O. or N.C. auxiliary contact or 4 power poles., Sizes 1.3: 3 power poles with side mounted N.O. / N.C. auxiliary contact or 4 power poles, Sizes 4.8: 3 main poles with 2 auxiliary contacts (1 N.O. and 1 N.C.) |
| Continuous ampere rating | : | 3-poles: 18 A |
| Electromagnetic compatibility | : | IEC 60947-1 - Environment A and B |
| Energy-efficient coil, hold-in | : | 1.7VA/1.7 W @ 24-60V AC, 20-60V DC |
| Energy-efficient coil, pick-up | : | 16VA/12.16 W @ 24-60V AC, 20-60V DC |
| FLA | : | 25A @ 600V, 3-phase per UL/CSA HVAC applications |
| Function | : | Energy-saving contactor |
| Fuse type | : | H, J, R |
| Heat dissipation | : | 4.7 W |
| Horsepower rating, max | : | 3-poles: 5Hp @ 575V, three-phase, full-load current must not exceed continuous Aere rating (60 Hz) |
| LRA | : | 150 A @ 440-480V AC, 3-phase per UL/CSA HVAC applications |
| NEMA size | : | 00.8 |
| Operating limits, dropout | : | (≤0.60) x Us @ DC control |
| Operating limits, pick-up | : | (0.80.1.1) x Us @ DC control |
| Operating time, closing delay | : | 15 ms |
| Operating time, opening delay | : | 10 ms |
| Operating volt amperes | : | 8VA @ 50/60 Hz, sealed |
| Optional accessories | : | Side- or front-mount auxiliary contacts, Mechanical interlocks, Terminal lugs, Terminal shields, Connecting bars |
| Power dissipation | : | 1 W per pole at Ie, AC-1, 400V |
| Switching of DC loads | : | 3-poles in series: 27A @ 220V (Shunt-wound motors starting, reverse current breaking, reversing, stepping DC-3 at 60 °C) |
| Switching of lighting loads | : | Tungsten lA: 25A @ 600V, 3-phase (break all lines) per UL/CSA |
| Total power dissipation | : | 2.6 W at Ie, AC-3, 400V, AC/DC control (120-250V) |
| Voltage type for actuating | : | AC/DC |
Construction | ||
| Required torque | : | Load: 22 lbin |
| Wire size | : | Load: 16.10 AWG for power terminals |
Mechanical | ||
| Altitude, max | : | 2000 m of installation site |
| Mechanical life | : | 13 mons of ops |
| Operating time, drop-out | : | 10 ms |
| Operating time, pick-up | : | 15 ms |
| Protection class | : | Contactor main contact: IP2X |
| Shock resistance | : | IEC 60068-2-27 |
| Switching frequency, max | : | 600 ops/hr, AC-1 |
| Vibration resistance | : | IEC 60068-2-6 |
| Weight | : | AC/DC (electronic): 0.43 kg (0.95 lbs.) |
Standards Protection | ||
| Ambient temperature | : | Storage range: -55.80 °C (-67.176 °F) |
| Climatic withstand | : | Category B according to IEC 60947-1, annex Q |
| Humidity | : | Non-condensing: 5.95% |
| Operating position | : | Vertical |
Overview | ||
| Standard Warranty Duration | : | 1 year |
Specifications | ||
| Storage range | : | -55.80 °C (-67.176 °F) |
| Build America, Buy America | : | No |
| Repair Options Available | : | No |
| DIN fuses (gG) current rating | : | Type 2 : 32A @ 400V, 100 kA available fault current |
| General purpose current | : | 16A @ 600V per UL/CSA |
| MCCB current rating | : | Type 2 : 28A @ 400V, 70 kA available fault current |
| Rated isolation voltage | : | 690V per IEC |
| Rated operational current | : | 9A @ 690V, Star-Delta starting (50 Hz) |
| Rated operational power | : | 7.5 kW @ 690V, AC-2, AC-3 switching of 3-phase motors (50 Hz), ambient temperature 60 °C (140 °F) |
| Rated voltage | : | 24V @ 48V, 110V @ 220V, 440V DC |
| Short time withstand | : | 3-pole: 80A @ 30s (40 °C) |
| UL class RK5 fuses rating | : | Type 1 Combination : 30A @ 600V, 5 kA available fault current |
| Country of Origin | : | France |
- China CCC
- 2000 m of installation site altitude, max
- UL Listed
- 65,000A @ 480V max, circuit breaker, RMS symmetrical
- Eurasion Economic Community
- Category B according to IEC 60947-1, annex Q
- Australian RCM
- Electronic coil
- Korean KC
- 30.60% x voltage @ 50/60 Hz
- UKCA DOC
- 85.10% x voltage @ 50/60 Hz
- Sizes 0.3: 3 power poles with internal N.O. or N.C. auxiliary contact or 4 power poles., Sizes 1.3: 3 power poles with side mounted N.O. / N.C. auxiliary contact or 4 power poles, Sizes 4.8: 3 main poles with 2 auxiliary contacts (1 N.O. and 1 N.C.)
Power Electrical Characteristics
Available short circuit ampere : 65,000A @ 480V max, circuit breaker, RMS symmetrical Coil : Electronic Coil operating limits, dropout : 30.60% x voltage @ 50/60 Hz Coil operating limits, pick-up : 85.10% x voltage @ 50/60 Hz Contacts : Sizes 0.3: 3 power poles with internal N.O. or N.C. auxiliary contact or 4 power poles., Sizes 1.3: 3 power poles with side mounted N.O. / N.C. auxiliary contact or 4 power poles, Sizes 4.8: 3 main poles with 2 auxiliary contacts (1 N.O. and 1 N.C.) Continuous ampere rating : 3-poles: 18 A Electromagnetic compatibility : IEC 60947-1 - Environment A and B Energy-efficient coil, hold-in : 1.7VA/1.7 W @ 24-60V AC, 20-60V DC Energy-efficient coil, pick-up : 16VA/12.16 W @ 24-60V AC, 20-60V DC FLA : 25A @ 600V, 3-phase per UL/CSA HVAC applications Function : Energy-saving contactor Fuse type : H, J, R Heat dissipation : 4.7 W Horsepower rating, max : 3-poles: 5Hp @ 575V, three-phase, full-load current must not exceed continuous Aere rating (60 Hz) LRA : 150 A @ 440-480V AC, 3-phase per UL/CSA HVAC applications NEMA size : 00.8 Operating limits, dropout : (≤0.60) x Us @ DC control Operating limits, pick-up : (0.80.1.1) x Us @ DC control Operating time, closing delay : 15 ms Operating time, opening delay : 10 ms Operating volt amperes : 8VA @ 50/60 Hz, sealed Optional accessories : Side- or front-mount auxiliary contacts, Mechanical interlocks, Terminal lugs, Terminal shields, Connecting bars Power dissipation : 1 W per pole at Ie, AC-1, 400V Switching of DC loads : 3-poles in series: 27A @ 220V (Shunt-wound motors starting, reverse current breaking, reversing, stepping DC-3 at 60 °C) Switching of lighting loads : Tungsten lA: 25A @ 600V, 3-phase (break all lines) per UL/CSA Total power dissipation : 2.6 W at Ie, AC-3, 400V, AC/DC control (120-250V) Voltage type for actuating : AC/DC Construction
Required torque : Load: 22 lbin Wire size : Load: 16.10 AWG for power terminals Mechanical
Altitude, max : 2000 m of installation site Mechanical life : 13 mons of ops Operating time, drop-out : 10 ms Operating time, pick-up : 15 ms Protection class : Contactor main contact: IP2X Shock resistance : IEC 60068-2-27 Switching frequency, max : 600 ops/hr, AC-1 Vibration resistance : IEC 60068-2-6 Weight : AC/DC (electronic): 0.43 kg (0.95 lbs.) Standards Protection
Ambient temperature : Storage range: -55.80 °C (-67.176 °F) Climatic withstand : Category B according to IEC 60947-1, annex Q Humidity : Non-condensing: 5.95% Operating position : Vertical Overview
Standard Warranty Duration : 1 year Specifications
Storage range : -55.80 °C (-67.176 °F) Build America, Buy America : No Repair Options Available : No DIN fuses (gG) current rating : Type 2 : 32A @ 400V, 100 kA available fault current General purpose current : 16A @ 600V per UL/CSA MCCB current rating : Type 2 : 28A @ 400V, 70 kA available fault current Rated isolation voltage : 690V per IEC Rated operational current : 9A @ 690V, Star-Delta starting (50 Hz) Rated operational power : 7.5 kW @ 690V, AC-2, AC-3 switching of 3-phase motors (50 Hz), ambient temperature 60 °C (140 °F) Rated voltage : 24V @ 48V, 110V @ 220V, 440V DC Short time withstand : 3-pole: 80A @ 30s (40 °C) UL class RK5 fuses rating : Type 1 Combination : 30A @ 600V, 5 kA available fault current Country of Origin : France - Downloads
Spec Sheet
General 1
General 2
Data Sheet