Fuse Amp-Trap 2000® 250V 0.3A Time-Delay Class RK1 A2D Series
MFG #A2D3/10R
Product Description:
Amp-Trap 2000 SmartSpot time-delay A2D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A2D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A2D-R fuses can be used to replace older 250V Class H, K or RK5 fuses already installed in the field.
HESCO Part Number
MERA2D3/10R
UPC
782001990589
Manufacturer Part Number
A2D3/10R
Manufacturer
Mersen
Fuse Amp-Trap 2000® 250V 0.3A Time-Delay Class RK1 A2D Series
MFG #A2D3/10R
Product Description:
Amp-Trap 2000 SmartSpot time-delay A2D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A2D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A2D-R fuses can be used to replace older 250V Class H, K or RK5 fuses already installed in the field.
HESCO Part Number
MERA2D3/10R
UPC
782001990589
Manufacturer Part Number
A2D3/10R
Manufacturer
Mersen
- Features
- Specifications
- Resources
- Solid state SmartSpot visual blown fuse indicator
- UL listed to standard 248-12 File E2137
- Motors
- Time-delay for motor starting and transformer inrush currents without nuisance opening
- DC listed to UL standard 248
- Safety switches
- 600VAC & 600VDC dual rated
- CSA certified to standard C22.2 No. 248.12
- Transformers
- 300kA interrupting rating - self-certified, UL witnessed tests
- Branch circuit protection
- Extremely current-limiting for low peak let-thru current
- Disconnects
- Recommended for Arc Flash energy reduction
- Control panels
- Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”
- All general-purpose circuits
- Rejection-style design prevents replacement errors (when used with recommended fuse blocks)
- High-visibility orange label gives instant brand recognition
- Reduced inventory by taking the place of class RK5, K, and H fuses
- Metal-embossed date and catalog number for easier traceability and lasting identification
- Fiberglass body provides dimensional stability in harsh industrial settings
Packaging Dimensions
Sell Pack Quantity | : | 10 Each |
Sell Pack Weight | : | 0.42 lb |
Sell Pack Width | : | 2.06 in |
Sell Pack Length | : | 3 in |
Sell Pack Height | : | 1.19 in |
Product Dimensions | ||
Product Weight | : | 0.04 lb |
Product Diameter | : | 0.56 in |
Product Length | : | 2 in |
Specifications | ||
Rated voltage AC UL | : | 250 V |
Rated voltage DC UL | : | 250 V |
Ampere Rating | : | 0.3 A |
ROHS Compliant | : | Yes |
Fuse Class | : | Class RK1 |
Speed/Characteristic | : | Time Delay |
Mounting | : | Clip |
AC Max I.R./Breaking Capacity: I1 | : | 200 kA |
Connection/Terminal Material | : | Tin-Plated Copper |
Connection/Terminal Type | : | Ferrule |
Body/Insulating Material | : | PolyTube |
- Solid state SmartSpot visual blown fuse indicator
- UL listed to standard 248-12 File E2137
- Motors
- Time-delay for motor starting and transformer inrush currents without nuisance opening
- DC listed to UL standard 248
- Safety switches
- 600VAC & 600VDC dual rated
- CSA certified to standard C22.2 No. 248.12
- Transformers
- 300kA interrupting rating - self-certified, UL witnessed tests
- Branch circuit protection
- Extremely current-limiting for low peak let-thru current
- Disconnects
- Recommended for Arc Flash energy reduction
- Control panels
- Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”
- All general-purpose circuits
- Rejection-style design prevents replacement errors (when used with recommended fuse blocks)
- High-visibility orange label gives instant brand recognition
- Reduced inventory by taking the place of class RK5, K, and H fuses
- Metal-embossed date and catalog number for easier traceability and lasting identification
- Fiberglass body provides dimensional stability in harsh industrial settings
Packaging Dimensions
Sell Pack Quantity : 10 Each Sell Pack Weight : 0.42 lb Sell Pack Width : 2.06 in Sell Pack Length : 3 in Sell Pack Height : 1.19 in Product Dimensions
Product Weight : 0.04 lb Product Diameter : 0.56 in Product Length : 2 in Specifications
Rated voltage AC UL : 250 V Rated voltage DC UL : 250 V Ampere Rating : 0.3 A ROHS Compliant : Yes Fuse Class : Class RK1 Speed/Characteristic : Time Delay Mounting : Clip AC Max I.R./Breaking Capacity: I1 : 200 kA Connection/Terminal Material : Tin-Plated Copper Connection/Terminal Type : Ferrule Body/Insulating Material : PolyTube - Downloads
Spec Sheet
Spec Sheet FR
Drawings