HESCO
Fuse Amp-Trap 2000® 250V 0.3A Time-Delay Class RK1 A2D Series

Fuse Amp-Trap 2000® 250V 0.3A Time-Delay Class RK1 A2D Series

MFG #A2D3/10R

Price Not Available
Product Description:
Amp-Trap 2000 SmartSpot time-delay A2D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A2D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A2D-R fuses can be used to replace older 250V Class H, K or RK5 fuses already installed in the field.
HESCO Part Number
MERA2D3/10R
UPC
782001990589
Manufacturer Part Number
A2D3/10R
Manufacturer
Mersen

Fuse Amp-Trap 2000® 250V 0.3A Time-Delay Class RK1 A2D Series

MFG #A2D3/10R

Product Description:
Amp-Trap 2000 SmartSpot time-delay A2D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A2D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A2D-R fuses can be used to replace older 250V Class H, K or RK5 fuses already installed in the field.
HESCO Part Number
MERA2D3/10R
UPC
782001990589
Manufacturer Part Number
A2D3/10R
Manufacturer
Mersen
Price Not Available
  • Solid state SmartSpot visual blown fuse indicator
  • UL listed to standard 248-12 File E2137
  • Motors
  • Time-delay for motor starting and transformer inrush currents without nuisance opening
  • DC listed to UL standard 248
  • Safety switches
  • 600VAC & 600VDC dual rated
  • CSA certified to standard C22.2 No. 248.12
  • Transformers
  • 300kA interrupting rating - self-certified, UL witnessed tests
  • Branch circuit protection
  • Extremely current-limiting for low peak let-thru current
  • Disconnects
  • Recommended for Arc Flash energy reduction
  • Control panels
  • Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”
  • All general-purpose circuits
  • Rejection-style design prevents replacement errors (when used with recommended fuse blocks)
  • High-visibility orange label gives instant brand recognition
  • Reduced inventory by taking the place of class RK5, K, and H fuses
  • Metal-embossed date and catalog number for easier traceability and lasting identification
  • Fiberglass body provides dimensional stability in harsh industrial settings