ProSoft Technology’s EtherNet/IP™ to Modbus® TCP/IP communication gateway allows high-speed bi-directional data transfers between Rockwell Automation® PACs and Schneider Electric® PACs. Our Modbus® TCP/IP driver features multiple client and server functionality, for faster data transmission. Two separate Ethernet ports allow each protocol to reside on separate subnets, allowing you to pass data between the two subnets without changing each device’s IP address. In addition, the gateway includes an embedded EDS Add-On Profile, allowing for simplified integration and reduced commissioning time.
HESCO Part Number
PROPLX32EIPMBTCP
Manufacturer Part Number
PLX32-EIP-MBTCP
Manufacturer
Prosoft Technology
EtherNet/IP to Modbus TCP/IP Communications Gateway
MFG #PLX32-EIP-MBTCP
Product Description:
ProSoft Technology’s EtherNet/IP™ to Modbus® TCP/IP communication gateway allows high-speed bi-directional data transfers between Rockwell Automation® PACs and Schneider Electric® PACs. Our Modbus® TCP/IP driver features multiple client and server functionality, for faster data transmission. Two separate Ethernet ports allow each protocol to reside on separate subnets, allowing you to pass data between the two subnets without changing each device’s IP address. In addition, the gateway includes an embedded EDS Add-On Profile, allowing for simplified integration and reduced commissioning time.
HESCO Part Number
PROPLX32EIPMBTCP
Manufacturer Part Number
PLX32-EIP-MBTCP
Manufacturer
Prosoft Technology
$1,436.46 / E
Each
Each
- Features
- Specifications
- Resources
- Two separate Ethernet ports allow each protocol to reside on separate subnets. This allows you to pass data between the two subnets without changing each device’s IP address to be on the same subnet.
- Data prioritization: Multiple I/O connections allow you to set RPIs for status and/or control data.
- Includes an embedded EDS Add-On Profile, allowing for simplified integration and reduced commissioning time.
- Gateway includes a SD card slot (SD card optional) for storing configuration files. This can be used for disaster recovery.
Specifications
Platform | : | All |
Mounting Method | : | DIN Rail |
Protocol | : | Modbus TCP/IP || Ethernet/IP |
Power Supply | : | 24 VDC nominal |
Power Supply | : | 10 to 36 VDC allowed |
Power Supply | : | Positive, Negative, GND Terminals |
Current Load | : | 24 VDC nominal @ 300 mA |
Current Load | : | 10 to 36 VDC @ 610 mA maximum |
Operating Temperature | : | -25°C to 70°C (-13°F to 158°F) |
Storage Temperature | : | 40°C to 80°C (-40°F to 176°F) |
Relative Humidity | : | 5% to 95% RH with no condensation |
Dimensions (H x W x D) | : | 5.38 x 1.99 x 4.38 in 13.67 x 5.05 x 11.13 cm |
- Two separate Ethernet ports allow each protocol to reside on separate subnets. This allows you to pass data between the two subnets without changing each device’s IP address to be on the same subnet.
- Data prioritization: Multiple I/O connections allow you to set RPIs for status and/or control data.
- Includes an embedded EDS Add-On Profile, allowing for simplified integration and reduced commissioning time.
- Gateway includes a SD card slot (SD card optional) for storing configuration files. This can be used for disaster recovery.
Specifications
Platform : All Mounting Method : DIN Rail Protocol : Modbus TCP/IP || Ethernet/IP Power Supply : 24 VDC nominal Power Supply : 10 to 36 VDC allowed Power Supply : Positive, Negative, GND Terminals Current Load : 24 VDC nominal @ 300 mA Current Load : 10 to 36 VDC @ 610 mA maximum Operating Temperature : -25°C to 70°C (-13°F to 158°F) Storage Temperature : 40°C to 80°C (-40°F to 176°F) Relative Humidity : 5% to 95% RH with no condensation Dimensions (H x W x D) : 5.38 x 1.99 x 4.38 in 13.67 x 5.05 x 11.13 cm - Downloads