Allen-Bradley
837 Temperature Controls, Style A, Remote Bulb and Capillary, 190 degrees F, Type 4 & 13 Metallic Aluminum enclosure
MFG #837-A4JX706
$1,384.05 / E
Each
Each
Product Description:
Electro-Mech Temp Cntrl Sw, NEMA Type 4&13, No Pilot Light, Standard Contact Block - SPST, Cu Capillary and bulb Bz armor, 6 Feet Capillary Length, 80…190°F, Max Temp 240°F, Standard Trip/Reset Setting
HESCO Part Number
AB837A4JX706
UPC
662073294108
Manufacturer Part Number
837-A4JX706
Manufacturer
Allen-Bradley
Allen-Bradley
837 Temperature Controls, Style A, Remote Bulb and Capillary, 190 degrees F, Type 4 & 13 Metallic Aluminum enclosure
MFG #837-A4JX706
Product Description:
Electro-Mech Temp Cntrl Sw, NEMA Type 4&13, No Pilot Light, Standard Contact Block - SPST, Cu Capillary and bulb Bz armor, 6 Feet Capillary Length, 80…190°F, Max Temp 240°F, Standard Trip/Reset Setting
HESCO Part Number
AB837A4JX706
UPC
662073294108
Manufacturer Part Number
837-A4JX706
Manufacturer
Allen-Bradley
$1,384.05 / E
Each
Each
- Features
- Specifications
- Adjustable differential from 2...87 °F
- Wide variety of contact arrangements
- Standard capillary length is 6 ft with custom lengths available
- Protective armor available in bronze or stainless steel
- Adjustable ranges from -60...570 °F
- Direct vertical and horizontal immersion available
Temperature Controls
Hazardous Location | : | No |
Device Style | : | Style A, Remote Bulb and Capillary |
Custom Trip or Reset Setting | : | Default Factory Setting |
Temperature Specifications | ||
Temperature Specifications | : | 190 degrees F |
Bulb And Capillary | ||
Type of Bulb and Capillary | : | Copper Capillary and Bulb Bronze Armor |
Length of Capillary | : | 6 feet |
Modified Industrial Control Options | ||
LED option | : | No LED pilot option |
Enclosure | ||
Enclosure Type | : | Type 4 & 13 Metallic Aluminum enclosure |
Modifications | ||
Factory Modifications | : | No Modifications |
Notes | ||
Standard Contacts | : | Standard contact block is supplied - Single-pole, double-throw, snap action. Supplied when a contact block suffix is not added to the catalog number. Non-inductive ratings, 5A, 240V. 3A, 600V. Control circuit ratings AC - 125 VA, 24...600V. DC - 57.5 VA, 115...230V. |
Note===> | : | NOTE: NEMA does not rate contacts to switch low voltage and current. Bulletin 837 Styles A, H, and V Temperature Controls are supplied with silver contacts. The devices are designed to deliver high force snap action to the contacts. This provides exceptional contact fidelity at 24V DC I/O card current level entry when the integrity of the enclosure is maintained. |
- Adjustable differential from 2...87 °F
- Wide variety of contact arrangements
- Standard capillary length is 6 ft with custom lengths available
- Protective armor available in bronze or stainless steel
- Adjustable ranges from -60...570 °F
- Direct vertical and horizontal immersion available
Temperature Controls
Hazardous Location : No Device Style : Style A, Remote Bulb and Capillary Custom Trip or Reset Setting : Default Factory Setting Temperature Specifications
Temperature Specifications : 190 degrees F Bulb And Capillary
Type of Bulb and Capillary : Copper Capillary and Bulb Bronze Armor Length of Capillary : 6 feet Modified Industrial Control Options
LED option : No LED pilot option Enclosure
Enclosure Type : Type 4 & 13 Metallic Aluminum enclosure Modifications
Factory Modifications : No Modifications Notes
Standard Contacts : Standard contact block is supplied - Single-pole, double-throw, snap action. Supplied when a contact block suffix is not added to the catalog number. Non-inductive ratings, 5A, 240V. 3A, 600V. Control circuit ratings AC - 125 VA, 24...600V. DC - 57.5 VA, 115...230V. Note===> : NOTE: NEMA does not rate contacts to switch low voltage and current. Bulletin 837 Styles A, H, and V Temperature Controls are supplied with silver contacts. The devices are designed to deliver high force snap action to the contacts. This provides exceptional contact fidelity at 24V DC I/O card current level entry when the integrity of the enclosure is maintained.