ÖLFLEX® 190 CY 5G6 10/5C
MFG #601005CY
$11.08 / E
(Must order in increments of 2500/E)
(Must order in increments of 2500/E)
Product Description:
Power and control cable; 5G6; Conductor identification: Numbers; Shielded; UL listed; Flexible
HESCO Part Number
OLF601005CY
Manufacturer Part Number
601005CY
Manufacturer
LAPP/OLFLEX
ÖLFLEX® 190 CY 5G6 10/5C
MFG #601005CY
Product Description:
Power and control cable; 5G6; Conductor identification: Numbers; Shielded; UL listed; Flexible
HESCO Part Number
OLF601005CY
Manufacturer Part Number
601005CY
Manufacturer
LAPP/OLFLEX
$11.08 / E
(Must order in increments of 2500/E)
(Must order in increments of 2500/E)
- Features
- Specifications
- Resources
- Conveyor systems
- Oil resistance
Specifications
| Basic material of cable insulation | : | Thermoplastic |
| Cable dimensions | : | 5G6 |
| Cable form | : | Round |
| CE marking | : | Yes |
| Chemical resistant | : | Yes |
| Conductor cross-section (mm2) | : | 6 mm² |
| Conductor design | : | IEC 60228 class 5: fine-wire |
| Conductor identification | : | Numbers |
| Conductor insulation basic material | : | Polyvinylchloride |
| Conductor material | : | Bare Copper |
| Copper index (lb) | : | 2548.000 lb/10000 ft |
| CSA certification | : | AWM I A after CSA C22.2 No. 210;AWM I B after CSA C22.2 No. 210;AWM II A after CSA C22.2 No. 210;AWM II B after CSA C22.2 No. 210 |
| CSA certified | : | Yes |
| cUL listed | : | No |
| cUR recognized | : | No |
| Ecolab certified | : | No |
| Flame retardance according to | : | UL Vertical-Tray Flame Test;CSA FT4 |
| Flame-retardant | : | Yes |
| For torsional load | : | Yes |
| Halogen-free | : | No |
| HAR certified | : | No |
| Including protective conductor | : | Yes |
| Leading conductor cross-section | : | mm² |
| Mechanically resistant | : | Yes |
| Minimum bending radius in inch, occasionally moved | : | 4.134 in |
| Minimum bending radius in inch, stationary | : | 4.134 in |
| Minimum bending radius, fixed installation | : | 6 x outer diameter |
| Minimum bending radius, occasionally flexing | : | 6 x outer diameter |
| Nominal conductor cross-section (AWG) | : | 10 AWG |
| Nominal outer diameter | : | 0.689 in |
| Nominal values | : | Unless specified otherwise, the product values shown are rated values at room temperature. You can receive additional values, such as tolerances, upon request if they are available and have been released for publication. |
| Number of conductors | : | 5 |
| Oil resistance according to | : | UL OILRES I;UL OILRES II;UL AWM Style 21098 |
| Oil-resistant | : | Yes |
| Optical degree of coverage of the stranded shielding, overall shield | : | 85 % |
| Outer jacket color | : | gray |
| Ozone-resistant | : | Yes |
| Product type | : | Power and control cable |
| Rated voltage | : | 600 V AC rms after UL TC;1000 V AC rms after UL AWM;1000 V AC rms after CSA AWM;1000 V AC rms after UL WTTC |
| Release date PM | : | 2022-05-19 16:22:47 |
| SAP Product Owner | : | LAPP USA INC. |
| Shielded | : | Yes |
| Suitable for use in accordance with NEC chapter 5 | : | Class I Division 2 |
| Temperature, fixed installation | : | -25 °C to 90 °C after UL/CSA TC;-40 °C to 105 °C after UL AWM |
| Temperature, occasionally flexing | : | -25 °C to 90 °C |
| Test voltage | : | 2 kV |
| Torsion | : | for +/- 150 °/m and min. -40 °C up to 2000 Torsion cycles;for +/- 150 °/m and min. 5 °C up to 5000 Torsion cycles |
| Type of overall shielding | : | Tin-plated copper braiding |
| UKCA marked | : | Yes |
| UL AWM certification | : | 2587 after UL 758 |
| UL certification | : | UL TC-ER after UL 1277;UL WTTC after UL 2277 |
| UL listed | : | Yes |
| UL recognized | : | Yes |
| UV-resistant | : | Yes |
| UV-resistant according to | : | UL sunlight resistant |
| VDE certified | : | No |
| Water-resistant | : | Yes |
| Weather-resistant | : | Yes |
- Conveyor systems
- Oil resistance
Specifications
Basic material of cable insulation : Thermoplastic Cable dimensions : 5G6 Cable form : Round CE marking : Yes Chemical resistant : Yes Conductor cross-section (mm2) : 6 mm² Conductor design : IEC 60228 class 5: fine-wire Conductor identification : Numbers Conductor insulation basic material : Polyvinylchloride Conductor material : Bare Copper Copper index (lb) : 2548.000 lb/10000 ft CSA certification : AWM I A after CSA C22.2 No. 210;AWM I B after CSA C22.2 No. 210;AWM II A after CSA C22.2 No. 210;AWM II B after CSA C22.2 No. 210 CSA certified : Yes cUL listed : No cUR recognized : No Ecolab certified : No Flame retardance according to : UL Vertical-Tray Flame Test;CSA FT4 Flame-retardant : Yes For torsional load : Yes Halogen-free : No HAR certified : No Including protective conductor : Yes Leading conductor cross-section : mm² Mechanically resistant : Yes Minimum bending radius in inch, occasionally moved : 4.134 in Minimum bending radius in inch, stationary : 4.134 in Minimum bending radius, fixed installation : 6 x outer diameter Minimum bending radius, occasionally flexing : 6 x outer diameter Nominal conductor cross-section (AWG) : 10 AWG Nominal outer diameter : 0.689 in Nominal values : Unless specified otherwise, the product values shown are rated values at room temperature. You can receive additional values, such as tolerances, upon request if they are available and have been released for publication. Number of conductors : 5 Oil resistance according to : UL OILRES I;UL OILRES II;UL AWM Style 21098 Oil-resistant : Yes Optical degree of coverage of the stranded shielding, overall shield : 85 % Outer jacket color : gray Ozone-resistant : Yes Product type : Power and control cable Rated voltage : 600 V AC rms after UL TC;1000 V AC rms after UL AWM;1000 V AC rms after CSA AWM;1000 V AC rms after UL WTTC Release date PM : 2022-05-19 16:22:47 SAP Product Owner : LAPP USA INC. Shielded : Yes Suitable for use in accordance with NEC chapter 5 : Class I Division 2 Temperature, fixed installation : -25 °C to 90 °C after UL/CSA TC;-40 °C to 105 °C after UL AWM Temperature, occasionally flexing : -25 °C to 90 °C Test voltage : 2 kV Torsion : for +/- 150 °/m and min. -40 °C up to 2000 Torsion cycles;for +/- 150 °/m and min. 5 °C up to 5000 Torsion cycles Type of overall shielding : Tin-plated copper braiding UKCA marked : Yes UL AWM certification : 2587 after UL 758 UL certification : UL TC-ER after UL 1277;UL WTTC after UL 2277 UL listed : Yes UL recognized : Yes UV-resistant : Yes UV-resistant according to : UL sunlight resistant VDE certified : No Water-resistant : Yes Weather-resistant : Yes - Downloads
Data Sheet - German