Meltric
DR30 Inlet, Poly, Blue, Size 2, Type 3R, 2P+N+G, 30A, 120/208 VAC, 60 Hz
MFG #31-18236-K16
$127.95Â /Â E
EACH
EACH
HESCO Part Number
MEL3118236K16
Manufacturer Part Number
31-18236-K16
Manufacturer
Meltric
Meltric
DR30 Inlet, Poly, Blue, Size 2, Type 3R, 2P+N+G, 30A, 120/208 VAC, 60 Hz
MFG #31-18236-K16
HESCO Part Number
MEL3118236K16
Manufacturer Part Number
31-18236-K16
Manufacturer
Meltric
$127.95Â /Â E
EACH
EACH
- Specifications
- Resources
Specifications
| Contact Configuration | :Â Â | 2P+N+G |
| Keying Position | :Â Â | 23 |
| Material | :Â Â | Poly |
| Color | :Â Â | Blue |
| Voltage Color Code | :Â Â | Blue |
| Rated Voltage | :Â Â | 120/208 VAC |
| Rated Current | :Â Â | 30A |
| Frequency | :Â Â | 60 Hz |
| Load Break, Normal Operation | :Â Â | 30A |
| Load Break, Abnormal Overload | :Â Â | 45A |
| NEMA Watertightness | :Â Â | 3R |
| Primary IP Rating | :Â Â | 54 |
| Minimum Operating Temperature | :Â Â | -40F (-40C) |
| Maximum Operating Temperature | :Â Â | 140F (60C) |
| Short Circuit Rating | :Â Â | 100 KA - MAKE & WITHSTAND |
| Short Circuit Rating, Fusing | :Â Â | 100 KA 80A (250%) RK1 NTD |
| Number of Auxiliary Contacts | :Â Â | NO AUX |
| Impact Rating | :Â Â | IK08 |
| Wire Temperature Rating | :Â Â | 60C |
| Phase Terminal Type | :Â Â | Screw terminal |
| Wiring Capacity | :Â Â | 14 AWG - 8 AWG |
| Wiring Capacity, Type W | :Â Â | 14 AWG - 8 AWG |
| Phase Cond. Strip Len. | :Â Â | 3/4 in (19 mm) |
| Phase Terminal Tightening Torque | :Â Â | 15 IN-LBS / 1.7 N-M |
| Number of Notch Positions | :Â Â | 24 |
| Mating Box | :Â Â | MB3 |
| Accessory Size | :Â Â | 2 |
| Product Line | :Â Â | 45 |
Certifications | ||
| UL Listing | :Â Â | UL || E79796 VOLUME 8 SECTION 1 || UL 1682 |
| CSA Listing | :Â Â | cCSAus || 155873 || C22.2 No. 182.1-13 |
Specifications
Contact Configuration :Â Â 2P+N+G Keying Position :Â Â 23 Material :Â Â Poly Color :Â Â Blue Voltage Color Code :Â Â Blue Rated Voltage :Â Â 120/208 VAC Rated Current :Â Â 30A Frequency :Â Â 60 Hz Load Break, Normal Operation :Â Â 30A Load Break, Abnormal Overload :Â Â 45A NEMA Watertightness :Â Â 3R Primary IP Rating :Â Â 54 Minimum Operating Temperature :Â Â -40F (-40C) Maximum Operating Temperature :Â Â 140F (60C) Short Circuit Rating :Â Â 100 KA - MAKE & WITHSTAND Short Circuit Rating, Fusing :Â Â 100 KA 80A (250%) RK1 NTD Number of Auxiliary Contacts :Â Â NO AUX Impact Rating :Â Â IK08 Wire Temperature Rating :Â Â 60C Phase Terminal Type :Â Â Screw terminal Wiring Capacity :Â Â 14 AWG - 8 AWG Wiring Capacity, Type W :Â Â 14 AWG - 8 AWG Phase Cond. Strip Len. :Â Â 3/4 in (19 mm) Phase Terminal Tightening Torque :Â Â 15 IN-LBS / 1.7 N-M Number of Notch Positions :Â Â 24 Mating Box :Â Â MB3 Accessory Size :Â Â 2 Product Line :Â Â 45 Certifications
UL Listing :Â Â UL || E79796 VOLUME 8 SECTION 1 || UL 1682 CSA Listing :Â Â cCSAus || 155873 || C22.2 No. 182.1-13 - Downloads
Catalog
Instructions