IEC 61850 Server Communication Module for ControlLogix
MFG #MVI56E-61850S
$4,488.89 / E
EACH
EACH
Product Description:
The MVI56E-61850S Ethernet Communication Module allows Rockwell Automation® ControlLogix® PACs to emulate Intelligent Electronic Devices on an IEC 61850 Ethernet network to SCADA systems. Now your non-smart electrical substation devices, such as transformers and switchgear, can present their data as IEC 61850 IEDs to the SCADA system. The module comes with an Add-On Instruction to be used with RSLogix™ 5000/Studio 5000™ for easier configuration and setup. Remote diagnostics of the unit can be viewed through controller tags in your ControlLogix® processor, reducing downtime.
HESCO Part Number
PROMVI56E61850S
Manufacturer Part Number
MVI56E-61850S
Manufacturer
Prosoft Technology
IEC 61850 Server Communication Module for ControlLogix
MFG #MVI56E-61850S
Product Description:
The MVI56E-61850S Ethernet Communication Module allows Rockwell Automation® ControlLogix® PACs to emulate Intelligent Electronic Devices on an IEC 61850 Ethernet network to SCADA systems. Now your non-smart electrical substation devices, such as transformers and switchgear, can present their data as IEC 61850 IEDs to the SCADA system. The module comes with an Add-On Instruction to be used with RSLogix™ 5000/Studio 5000™ for easier configuration and setup. Remote diagnostics of the unit can be viewed through controller tags in your ControlLogix® processor, reducing downtime.
HESCO Part Number
PROMVI56E61850S
Manufacturer Part Number
MVI56E-61850S
Manufacturer
Prosoft Technology
$4,488.89 / E
EACH
EACH
- Features
- Specifications
- Resources
- The ControlLogix® PAC is able to emulate multiple Intelligent Electronic Devices on an IEC 61850 network.
- Add-On Instruction provides logical definitions for I/O, module status and control data easing configuration and maintenance of the module.
- ProSoft Discovery Service (PDS) software is used to initially set the module’s IP address, so you don’t have to change your PC to the default subnet of the module.
- Module functions as an IEC 61850 Server, allowing it to interface with SCADA systems.
Specifications
| Protocol | : | IEC 61850 |
| Platform | : | ControlLogix |
| Mounting Method | : | Chassis |
| Client connections | : | Supports up to 8 independent client connections |
| Supported 61850 data point types | : | Status with Quality – 200 points |
| Supported 61850 data point types | : | SOE Status – 200 points |
| Supported 61850 data point types | : | Control Points – 200 points |
| Supported 61850 data point types | : | (FLOATDB type is 50 points maximum) |
| Supported 61850 data point types | : | Buffered Reports – 8 instances maximum |
| Supported 61850 data point types | : | Unbuffered Reports – 8 instances maximum |
| Supported functions | : | IEC 61850 Server functionality with support for the MMS Read and MMS Write functions using the GGIO logical node |
| Supported data types | : | GGIO logical node with support for the following data types: |
| Supported data types | : | BOOL |
| Supported data types | : | BYTE |
| Supported data types | : | INT |
| Supported data types | : | DINT (32-bit) |
| Supported data types | : | REAL (32-bit Float) |
| Supported data types | : | FLOATDB (32-bit Float) |
- The ControlLogix® PAC is able to emulate multiple Intelligent Electronic Devices on an IEC 61850 network.
- Add-On Instruction provides logical definitions for I/O, module status and control data easing configuration and maintenance of the module.
- ProSoft Discovery Service (PDS) software is used to initially set the module’s IP address, so you don’t have to change your PC to the default subnet of the module.
- Module functions as an IEC 61850 Server, allowing it to interface with SCADA systems.
Specifications
Protocol : IEC 61850 Platform : ControlLogix Mounting Method : Chassis Client connections : Supports up to 8 independent client connections Supported 61850 data point types : Status with Quality – 200 points Supported 61850 data point types : SOE Status – 200 points Supported 61850 data point types : Control Points – 200 points Supported 61850 data point types : (FLOATDB type is 50 points maximum) Supported 61850 data point types : Buffered Reports – 8 instances maximum Supported 61850 data point types : Unbuffered Reports – 8 instances maximum Supported functions : IEC 61850 Server functionality with support for the MMS Read and MMS Write functions using the GGIO logical node Supported data types : GGIO logical node with support for the following data types: Supported data types : BOOL Supported data types : BYTE Supported data types : INT Supported data types : DINT (32-bit) Supported data types : REAL (32-bit Float) Supported data types : FLOATDB (32-bit Float) - Downloads
MVI56E-61850S Datasheet
MVI56E-61850S FAQ
MVI56E-61850S Ladder Files
MVI56E-61850S User Manual