Fire Alarms XAL-53
MFG #XAL-53
$1,101.96 / E
Each
Each
Product Description:
Killark XCS Series Fire Alarm Station for Class 1 Division 1 & 2, Class 1 Zone 1 & 2 areas where Type 7 & 9 protection is required.
HESCO Part Number
KILXAL53
UPC
783936880389
Manufacturer Part Number
XAL-53
Manufacturer
Killark
Fire Alarms XAL-53
MFG #XAL-53
Product Description:
Killark XCS Series Fire Alarm Station for Class 1 Division 1 & 2, Class 1 Zone 1 & 2 areas where Type 7 & 9 protection is required.
HESCO Part Number
KILXAL53
UPC
783936880389
Manufacturer Part Number
XAL-53
Manufacturer
Killark
$1,101.96 / E
Each
Each
- Features
- Specifications
- Resources
- Class I, Divisions 1 & 2, Groups C, D
- Enclosure is made of copper free aluminum alloy
- Class I, Zones 1 & 2, Groups IIB, IIA
- Conduit openings are 3/4” NPT feed through.
- Class II, Divisions 1 & 2, Groups E, F, G
- Red, textured powder epoxy paint finish is standard on box and cover to provide high visibility for alarm station.
- Class III, Divisions 1 & 2
- Bilingual nameplates included per CSA requirement.
- Internal ground screw is standard.
- The alarm station is activated by lifting the front cover and pulling down ring. This quick easy to use two-step process prevents unintentional operation.
Dimensions
Depth | : | 4-1/2 |
Gross Weight with Packaging | : | 2.67 |
Height | : | 4 in |
Length | : | 7.5 in |
Weight | : | 2.67 lb |
Width | : | 6 in |
Certifications and Compliance | ||
CSA File Number | : | LR31085 |
UL File Number | : | E50498 |
General | ||
Action | : | SP |
Actuator | : | Lift Cover, Pull ring |
Ambient Temp. Range | : | UL: -25 to 40 ºC, CSA: -50 to 40 ºC, IEC: -20 to 40 °C |
Application | : | Hazardous areas due to the presence of flammable gases or vapors, combustible dusts, or easily ignitable fibers or flyings. Installation at petroleum refineries, chemical and petrochemical plants, storage areas, and other processing facilities where hazardous substances are handled or stored. Areas where emergency control of fire alarm or signal circuits is required. |
Back Box Type | : | SWB |
Color | : | Red |
Number Of Poles | : | 1 |
Series | : | XAL |
Type | : | Aluminum Fire Alarm Station With Pull-Ring Activation |
UPC | : | 783936880389 |
Electrical Ratings | ||
Amperage Rating | : | 10 A |
Contact Rating | : | 7200 VA (make), 720 VA (break), 10A cont. @ 600V AC; 2.5A cont. @ 600V DC. |
Frequency Rating | : | 50/60 Hz |
Logistics | ||
Carton Quantity | : | 1 EA |
Customer Notices
Prop 65 Notice
Certifications
XAL Series Fire Alarm UL Certification
Installation/Instruction Manual (IOM)
KIL_XAL Series Fire Alarm Station IOM_K0993
Specs
Spec Sheet

Certifications

Installation/Instruction Manual (IOM)

Specs

- Class I, Divisions 1 & 2, Groups C, D
- Enclosure is made of copper free aluminum alloy
- Class I, Zones 1 & 2, Groups IIB, IIA
- Conduit openings are 3/4” NPT feed through.
- Class II, Divisions 1 & 2, Groups E, F, G
- Red, textured powder epoxy paint finish is standard on box and cover to provide high visibility for alarm station.
- Class III, Divisions 1 & 2
- Bilingual nameplates included per CSA requirement.
- Internal ground screw is standard.
- The alarm station is activated by lifting the front cover and pulling down ring. This quick easy to use two-step process prevents unintentional operation.
Dimensions
Depth : 4-1/2 Gross Weight with Packaging : 2.67 Height : 4 in Length : 7.5 in Weight : 2.67 lb Width : 6 in Certifications and Compliance
CSA File Number : LR31085 UL File Number : E50498 General
Action : SP Actuator : Lift Cover, Pull ring Ambient Temp. Range : UL: -25 to 40 ºC, CSA: -50 to 40 ºC, IEC: -20 to 40 °C Application : Hazardous areas due to the presence of flammable gases or vapors, combustible dusts, or easily ignitable fibers or flyings. Installation at petroleum refineries, chemical and petrochemical plants, storage areas, and other processing facilities where hazardous substances are handled or stored. Areas where emergency control of fire alarm or signal circuits is required. Back Box Type : SWB Color : Red Number Of Poles : 1 Series : XAL Type : Aluminum Fire Alarm Station With Pull-Ring Activation UPC : 783936880389 Electrical Ratings
Amperage Rating : 10 A Contact Rating : 7200 VA (make), 720 VA (break), 10A cont. @ 600V AC; 2.5A cont. @ 600V DC. Frequency Rating : 50/60 Hz Logistics
Carton Quantity : 1 EA - Customer Notices
Prop 65 Notice
CertificationsXAL Series Fire Alarm UL Certification
Installation/Instruction Manual (IOM)KIL_XAL Series Fire Alarm Station IOM_K0993
SpecsSpec Sheet