Fuse Amp-Trap 2000® 600V 150A Time-Delay Class J AJT Series EI Indicator

Fuse Amp-Trap 2000® 600V 150A Time-Delay Class J AJT Series EI Indicator

MFG #AJT150EI

$375.35 / E
Each
Product Description:
Amp-Trap 2000® AJT fuses provide non-indication as well as a SmartSpot visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No Damage protection to main, feeder, and branch circuits, for all types of loads — yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT’s time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability.
HESCO Part Number
MERAJT150EI
UPC
782001961534
Manufacturer Part Number
AJT150EI
Manufacturer
Mersen

Fuse Amp-Trap 2000® 600V 150A Time-Delay Class J AJT Series EI Indicator

MFG #AJT150EI

Product Description:
Amp-Trap 2000® AJT fuses provide non-indication as well as a SmartSpot visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No Damage protection to main, feeder, and branch circuits, for all types of loads — yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT’s time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability.
HESCO Part Number
MERAJT150EI
UPC
782001961534
Manufacturer Part Number
AJT150EI
Manufacturer
Mersen
$375.35 / E
Each
  • UL listed to standard 248-8 File E2137
  • Non-indicating or solid state SmartSpot visual blown fuse indicator
  • Motor circuits
  • DC listed to UL standard 248
  • Time-delay for motor starting and transformer inrush
  • Mains
  • CSA certified to standard C22.2 No. 248.8
  • 300kA interrupting rating - self-certified, UL witnessed tests
  • Feeders
  • IEC 60269-2-1
  • Extremely current-limiting for low peak let-thru current
  • Branch circuits
  • UL listed
  • Most current-limiting UL class fuse
  • Lighting, heating & general loads
  • DC tested to UL standard 248
  • Recommended for Arc Flash energy reduction
  • Transformers
  • Small footprint requires less mounting space and allows smaller, more economical fuse blocks
  • Control panels
  • Easy 2-to-1 selectivity for prevention of nuisance shutdowns
  • Circuit breaker back-up
  • Unique Class J dimensions prevent replacement errors
  • Bus duct
  • High-visibility orange label gives instant brand recognition
  • Load centers
  • Metal-embossed date and catalog number for traceability and lasting identification
  • Fiberglass body provides dimensional stability in harsh industrial settings
  • High-grade silica filler ensures fast arc quenching
  • Optional EI indicator/switch mount for AJT70 to 600 open fuse indication