Modbus TCP/IP Lite Communication Module for CompactLogix

Modbus TCP/IP Lite Communication Module for CompactLogix

MFG #MVI69L-MBTCP

$1,186.11Ā /Ā E
Each
Product Description:
The MVI69L-MBTCP Modbus TCP/IP module is ideal for smaller applications that utilize the CompactLogix L2 controllers. The module has an Add-on Profile and an Add-on Instruction to reduce commissioning time.The MVI69L-MBTCP has a single Ethernet port for diagnostic and application data. It supports both Client and Server connectivity to interface with a variety of devices using the Modbus TCP/IP Protocol.
HESCO Part Number
PROMVI69LMBTCP
Manufacturer Part Number
MVI69L-MBTCP
Manufacturer
Prosoft Technology

Modbus TCP/IP Lite Communication Module for CompactLogix

MFG #MVI69L-MBTCP

Product Description:
The MVI69L-MBTCP Modbus TCP/IP module is ideal for smaller applications that utilize the CompactLogix L2 controllers. The module has an Add-on Profile and an Add-on Instruction to reduce commissioning time.The MVI69L-MBTCP has a single Ethernet port for diagnostic and application data. It supports both Client and Server connectivity to interface with a variety of devices using the Modbus TCP/IP Protocol.
HESCO Part Number
PROMVI69LMBTCP
Manufacturer Part Number
MVI69L-MBTCP
Manufacturer
Prosoft Technology
$1,186.11Ā /Ā E
Each
  • Supports CompactLogix processors with 1769 I/O bus capability version 16 and greater (MicroLogix 1500 not supported)
  • Add-on Instruction creates UDTs, providing logical definitions for I/O, status, and control data
  • Add-on Profile support, improving integration in the CompactLogix System
  • Diagnostic data available in processor controller tags, enabling decisions to be made based upon node health
  • Configuration backed up in CompactLogix project (ACD file)
  • Module acts as a co-processor reducing impact to PLC scan time
  • Supports up to 240 words of I/O data
  • Supports up to 10 Client and 10 Server connections simultaneously
  • Supports Enron and Daniel style Floating point data implementation
  • 1: Read Coil Status
  • 2: Read Input Status
  • 3: Read Holding Registers
  • 4: Read Input Registers
  • 5: Force (Write) Single Coil
  • 6: Preset (Write) Single Holding Register
  • 8: Diagnostics (Slave Only, Responds to Subfunction 00)
  • 15: Force( Write) Multiple Coils
  • 16: Preset (Write) Multiple Holding Registers
  • 17: Report Slave ID (Slave Only)
  • 22: Mask Write Holding Register (Slave Only)
  • 23: Read/Write Holding Registers (Slave Only)