HESCO
Copper Split Bolt, Conductor Range for Equal Main & Tap 2-6 Sol, UL, CSA

Copper Split Bolt, Conductor Range for Equal Main & Tap 2-6 Sol, UL, CSA

MFG #IK-2

Requires Quote
 / Each
Product Description:
ILSCO Split Bolt, Mechanical connection, Copper material, UL 467 Listed, UL 486A/B Listed, C22.2 No. 65, C22.2 No. 188, 1 conductors, 1 ports/wireways, Drive Type Main 11/16, 13/16 External Hex, rated for 35 kV, primary color Copper, Conductor range for solid equal run & tap 2 Sol - 6 Sol, Conductor range for stranded equal run & tap 2 Sol - 6 Sol, 1 poles,
HESCO Part Number
ILSIK2
UPC
0783669470109
Manufacturer Part Number
IK-2
Manufacturer
Ilsco

Copper Split Bolt, Conductor Range for Equal Main & Tap 2-6 Sol, UL, CSA

MFG #IK-2

Product Description:
ILSCO Split Bolt, Mechanical connection, Copper material, UL 467 Listed, UL 486A/B Listed, C22.2 No. 65, C22.2 No. 188, 1 conductors, 1 ports/wireways, Drive Type Main 11/16, 13/16 External Hex, rated for 35 kV, primary color Copper, Conductor range for solid equal run & tap 2 Sol - 6 Sol, Conductor range for stranded equal run & tap 2 Sol - 6 Sol, 1 poles,
HESCO Part Number
ILSIK2
UPC
0783669470109
Manufacturer Part Number
IK-2
Manufacturer
Ilsco
Requires Quote
 / Each

Voltage

Voltage Rating:  35 kV

Dimensions

Drive Size Main:  11/16, 13/16
Drive Type Main:  External Hex
Height BX (IN):  2
Weight BX (LB):  6.237
Width BX (IN):  6.1875
Wire Diameter Range Primary (IN):  0.162 - 0.292

Testing Standards

CSA File Number:  LR-701570
CSA Standard:  C22.2 No. 188, C22.2 No. 65
Prop65 Compliance:  WARNING: Cancer and Reproductive Harm - www.P65warnings.ca.gov
UL Control Number:  460C
UL / CULUS Specification:  UL 486A/B Listed, UL 467 Listed
UL File Number:  E6207

Additional Class Attributes

Connection:  Mechanical
Number of Conductors:  1
Number of Poles:  1

Material and Finish

Conductor Material:  Copper
Material:  Copper

Conductor Ranges

Conductor Range for Equal Run & Tap Str:  2 Str - 5 Str
Conductor Range for Equal Run & Tap Sol:  2 Sol - 6 Sol
Conductor Range for Minimum Tap with Maximum Run:  14 Str
Max Conductor Copperweld - Str:  3 No. 7
Max Conductor Copperweld - Type A:  3A

Additional Technical Specifications

Conductor Type:  Solid, Stranded

General

Bag Quantity:  1
Carton Quantity Description:  STD PACK QTY 50
Direct Burial:  Yes
Dual Rated:  No
NEMA Code:  S-588-4
UPC Code:  78366947010

Specifications

Height:  0.81 in
Length:  1.32 in
Weight:  0.106 lbs
Width:  0.94 in

Bolt and Screw Sizes

Number of Wire Binding Screws per Port:  1
Wire Binding Torque:  275

Color

Color:  Copper

Environment and Temperature

Temperature Rating:  90°C