Fuse Amp-Trap 2000® 600V 12A Time-Delay Class J AJT Series Smart-Spot
MFG #AJT12
$44.90 / E
Each
Each
Product Description:
Amp-Trap 2000® AJT fuses provide non-indication as well as a SmartSpot visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No Damage protection to main, feeder, and branch circuits, for all types of loads — yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT’s time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability.
HESCO Part Number
MERAJT12
UPC
782001963101
Manufacturer Part Number
AJT12
Manufacturer
Mersen
Fuse Amp-Trap 2000® 600V 12A Time-Delay Class J AJT Series Smart-Spot
MFG #AJT12
Product Description:
Amp-Trap 2000® AJT fuses provide non-indication as well as a SmartSpot visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No Damage protection to main, feeder, and branch circuits, for all types of loads — yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT’s time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability.
HESCO Part Number
MERAJT12
UPC
782001963101
Manufacturer Part Number
AJT12
Manufacturer
Mersen
$44.90 / E
Each
Each
- Features
- Specifications
- Resources
- UL listed to standard 248-8 File E2137
- Motor circuits
- Non-indicating or solid state SmartSpot visual blown fuse indicator
- DC listed to UL standard 248
- Mains
- Time-delay for motor starting and transformer inrush
- CSA certified to standard C22.2 No. 248.8
- Feeders
- 300kA interrupting rating - self-certified, UL witnessed tests
- IEC 60269-2-1
- Branch circuits
- Extremely current-limiting for low peak let-thru current
- UL listed
- Lighting, heating & general loads
- Most current-limiting UL class fuse
- DC tested to UL standard 248
- Transformers
- Recommended for Arc Flash energy reduction
- Control panels
- Small footprint requires less mounting space and allows smaller, more economical fuse blocks
- Circuit breaker back-up
- Easy 2-to-1 selectivity for prevention of nuisance shutdowns
- Bus duct
- Unique Class J dimensions prevent replacement errors
- Load centers
- High-visibility orange label gives instant brand recognition
- Metal-embossed date and catalog number for traceability and lasting identification
- Fiberglass body provides dimensional stability in harsh industrial settings
- High-grade silica filler ensures fast arc quenching
- Optional EI indicator/switch mount for AJT70 to 600 open fuse indication
Specifications
Rated voltage AC UL | : | 600 V |
Rated voltage DC UL | : | 500 V |
Frequency | : | 50/60 Hz |
Ampere Rating | : | 12 A |
ROHS Compliant | : | Yes |
Fuse Class | : | Class J |
Speed/Characteristic | : | Time Delay |
Mounting | : | Clip |
AC Max I.R./Breaking Capacity: I1 | : | 200 kA |
Indication System | : | Yes |
Indication System Type | : | SmartSpot® |
Connection/Terminal Material | : | Tin-Plated Copper |
Connection/Terminal Type | : | Ferrule |
Body/Insulating Material | : | GMG |
Product Dimensions | ||
Product Weight | : | 0.2 lb |
Product Diameter | : | 0.81 in |
Product Length | : | 2.25 in |
Packaging Dimensions | ||
Sell Pack Quantity | : | 10 Each |
Sell Pack Weight | : | 2.1 lb |
Sell Pack Width | : | 2.38 in |
Sell Pack Length | : | 4.25 in |
Sell Pack Height | : | 1.69 in |
- UL listed to standard 248-8 File E2137
- Motor circuits
- Non-indicating or solid state SmartSpot visual blown fuse indicator
- DC listed to UL standard 248
- Mains
- Time-delay for motor starting and transformer inrush
- CSA certified to standard C22.2 No. 248.8
- Feeders
- 300kA interrupting rating - self-certified, UL witnessed tests
- IEC 60269-2-1
- Branch circuits
- Extremely current-limiting for low peak let-thru current
- UL listed
- Lighting, heating & general loads
- Most current-limiting UL class fuse
- DC tested to UL standard 248
- Transformers
- Recommended for Arc Flash energy reduction
- Control panels
- Small footprint requires less mounting space and allows smaller, more economical fuse blocks
- Circuit breaker back-up
- Easy 2-to-1 selectivity for prevention of nuisance shutdowns
- Bus duct
- Unique Class J dimensions prevent replacement errors
- Load centers
- High-visibility orange label gives instant brand recognition
- Metal-embossed date and catalog number for traceability and lasting identification
- Fiberglass body provides dimensional stability in harsh industrial settings
- High-grade silica filler ensures fast arc quenching
- Optional EI indicator/switch mount for AJT70 to 600 open fuse indication
Specifications
Rated voltage AC UL : 600 V Rated voltage DC UL : 500 V Frequency : 50/60 Hz Ampere Rating : 12 A ROHS Compliant : Yes Fuse Class : Class J Speed/Characteristic : Time Delay Mounting : Clip AC Max I.R./Breaking Capacity: I1 : 200 kA Indication System : Yes Indication System Type : SmartSpot® Connection/Terminal Material : Tin-Plated Copper Connection/Terminal Type : Ferrule Body/Insulating Material : GMG Product Dimensions
Product Weight : 0.2 lb Product Diameter : 0.81 in Product Length : 2.25 in Packaging Dimensions
Sell Pack Quantity : 10 Each Sell Pack Weight : 2.1 lb Sell Pack Width : 2.38 in Sell Pack Length : 4.25 in Sell Pack Height : 1.69 in - Downloads
Spec Sheet
Spec Sheet FR
Drawings
Curves