PROFIBUS DPV1 Master for CompactLogix
MFG #ILX69-PBM
$1,959.00 / E
Each
Each
Product Description:
The ILX69-PBM PROFIBUS DPV1 Master module provides all the advantages of in-chassis PROFIBUS communication, such as the inclusion of an AOI and the Autoscan features which greatly reduce your commissioning time, and ComDTM that provides remote Ethernet connectivity with asset management software. With these modules, CompactLogix™ processors can easily communicate with slave devices supporting PROFIBUS DPV0 and DPV1 protocol. The module acts as an input/output module between the PROFIBUS network and the processor supporting complete Master specifications according to IEC 61158.
HESCO Part Number
PROILX69PBM
Manufacturer Part Number
ILX69-PBM
Manufacturer
Prosoft Technology
PROFIBUS DPV1 Master for CompactLogix
MFG #ILX69-PBM
Product Description:
The ILX69-PBM PROFIBUS DPV1 Master module provides all the advantages of in-chassis PROFIBUS communication, such as the inclusion of an AOI and the Autoscan features which greatly reduce your commissioning time, and ComDTM that provides remote Ethernet connectivity with asset management software. With these modules, CompactLogix™ processors can easily communicate with slave devices supporting PROFIBUS DPV0 and DPV1 protocol. The module acts as an input/output module between the PROFIBUS network and the processor supporting complete Master specifications according to IEC 61158.
HESCO Part Number
PROILX69PBM
Manufacturer Part Number
ILX69-PBM
Manufacturer
Prosoft Technology
$1,959.00 / E
Each
Each
- Features
- Specifications
- Resources
- AOI: Module communication is integrated within Studio/RSLogix 5000 using a sample Add-On Instruction (AOI), or sample ladderlogic file, reducing commissioning time.
- Autoscan: The new Autoscan feature reduces start up times and simplifies troubleshooting by scanning the PROFIBUS networkand uploading slave device addresses and configuration information. (Reads and maps nodes automatically to the module.)
- ComDTM: Allows remote Ethernet connectivity with Asset Management Software significantly lowering maintenance costs. You can configure, commission, maintain and diagnose your fieldbus devices throughout their entire lifecycle with thiscomprehensive, fully integrated engineering and maintenance environment.
- SD card slot (SD card optional) is used for storing configuration files in the event of a disaster. It can also be used to update thefirmware of the module without the need of a 1769 CPU.
- Auto-detection mode is supported
Hardware Specification
Specification | : | Description |
PROFIBUS Interface | : | RS-485, max. 12 Mbps, potential free, according EN 50170 |
Diagnostic Interface | : | 10/100 Ethernet, RJ48 |
Power Supply | : | +5 V ±5 % / 570 mA |
Max. Distance Rating | : | 2 slots |
Dimensions | : | Standard 1769 Single-slot module |
Burst | : | EN 61000-4-4, 2 kV, 5 kHz |
Surge | : | EN 61000-4-5, 2 kV common mode, 1 kVdifferential mode |
ESD | : | EN 61000-4-2, 4 kV contact, 8 kV air, 4 kV indirect |
Radiated/Conducted Immunity | : | EN 61000-4-3, 10 V/m, 30...1000 MHz, 80% AM, 1kHz sine wave |
Radiated/Conducted Immunity | : | EN 61000-4-6, 10 V, 0,15...30 MHz |
Radiated/Conducted Emission | : | EN 55011 Class A |
Vibration/Shock | : | IEC 600068-2-6, 10-150 Hz, ± 0,75 mm, ± 1 g, 1Octave/min |
Vibration/Shock | : | IEC 600068-2-27, 15 g, 11 ms |
Operating Temperature | : | 0°C to 60°C (32°F to 140°F) |
Relative Humidity | : | 5 to 95% (non-condensing) |
PROFIBUS conformance | : | Certified |
PROFIBUS DP Specifications | ||
Specification | : | Description |
Slaves | : | Maximum 125 |
Input/Output | : | Maximum 244 Bytes per Slave |
Input Data | : | Maximum 5712 Bytes |
Acyclic Data | : | DPV1 |
Status data | : | 88 Bytes |
Output data | : | Maximum 5760 Bytes |
DPV1 services | : | Class 1 Alarm |
DPV1 services | : | Class 2 Initiate/Read/Write/Data transport/Abort |
Services | : | Global-Control, Slave-Diagnostic, Set-Parameter |
Sync, Freeze Command | : | Supported |
Baud rate | : | 9.6 kBaud, 19.2 kBaud, 45.45 kBaud, 93.75 kBaud, 187.5 kBaud, 500 kBaud 1.5 MBaud, 3MBaud, 6 MBaud, 12 MBaud |
- AOI: Module communication is integrated within Studio/RSLogix 5000 using a sample Add-On Instruction (AOI), or sample ladderlogic file, reducing commissioning time.
- Autoscan: The new Autoscan feature reduces start up times and simplifies troubleshooting by scanning the PROFIBUS networkand uploading slave device addresses and configuration information. (Reads and maps nodes automatically to the module.)
- ComDTM: Allows remote Ethernet connectivity with Asset Management Software significantly lowering maintenance costs. You can configure, commission, maintain and diagnose your fieldbus devices throughout their entire lifecycle with thiscomprehensive, fully integrated engineering and maintenance environment.
- SD card slot (SD card optional) is used for storing configuration files in the event of a disaster. It can also be used to update thefirmware of the module without the need of a 1769 CPU.
- Auto-detection mode is supported
Hardware Specification
Specification : Description PROFIBUS Interface : RS-485, max. 12 Mbps, potential free, according EN 50170 Diagnostic Interface : 10/100 Ethernet, RJ48 Power Supply : +5 V ±5 % / 570 mA Max. Distance Rating : 2 slots Dimensions : Standard 1769 Single-slot module Burst : EN 61000-4-4, 2 kV, 5 kHz Surge : EN 61000-4-5, 2 kV common mode, 1 kVdifferential mode ESD : EN 61000-4-2, 4 kV contact, 8 kV air, 4 kV indirect Radiated/Conducted Immunity : EN 61000-4-3, 10 V/m, 30...1000 MHz, 80% AM, 1kHz sine wave Radiated/Conducted Immunity : EN 61000-4-6, 10 V, 0,15...30 MHz Radiated/Conducted Emission : EN 55011 Class A Vibration/Shock : IEC 600068-2-6, 10-150 Hz, ± 0,75 mm, ± 1 g, 1Octave/min Vibration/Shock : IEC 600068-2-27, 15 g, 11 ms Operating Temperature : 0°C to 60°C (32°F to 140°F) Relative Humidity : 5 to 95% (non-condensing) PROFIBUS conformance : Certified PROFIBUS DP Specifications
Specification : Description Slaves : Maximum 125 Input/Output : Maximum 244 Bytes per Slave Input Data : Maximum 5712 Bytes Acyclic Data : DPV1 Status data : 88 Bytes Output data : Maximum 5760 Bytes DPV1 services : Class 1 Alarm DPV1 services : Class 2 Initiate/Read/Write/Data transport/Abort Services : Global-Control, Slave-Diagnostic, Set-Parameter Sync, Freeze Command : Supported Baud rate : 9.6 kBaud, 19.2 kBaud, 45.45 kBaud, 93.75 kBaud, 187.5 kBaud, 500 kBaud 1.5 MBaud, 3MBaud, 6 MBaud, 12 MBaud - Downloads
ILX69-PBM Datasheet
ILX69-PBM User Manual
ILX69-PBM Add On Rung
ILX69-PBM/PBS FAQ
ProSoft fdt Configuration Manager V1.0.3.5247
ILX69-PBM EDS File
ILX69 - PBS/PBM - AOP