EtherNet/IP Client/Server Network Interface Module for SLC
MFG #MVI46-DFNT
$5,989.00Â /Â E
Each
Each
Product Description:
The EtherNet/IP Client/Server Network Interface Module allows SLC processors to interface with EtherNet/IP protocol (Explicit Messaging) compatible devices and hosts. The SLC 5/05 with the MVI46-DFNT module provides a second EtherNet/IP port to a separate subnet for communicating with a HMI or SCADA host. For other SLC processors the module provides a serial pass-thru channel 0 service for remote Ethernet programming and troubleshooting.
HESCO Part Number
PROMVI46DFNT
Manufacturer Part Number
MVI46-DFNT
Manufacturer
Prosoft Technology
EtherNet/IP Client/Server Network Interface Module for SLC
MFG #MVI46-DFNT
Product Description:
The EtherNet/IP Client/Server Network Interface Module allows SLC processors to interface with EtherNet/IP protocol (Explicit Messaging) compatible devices and hosts. The SLC 5/05 with the MVI46-DFNT module provides a second EtherNet/IP port to a separate subnet for communicating with a HMI or SCADA host. For other SLC processors the module provides a serial pass-thru channel 0 service for remote Ethernet programming and troubleshooting.
HESCO Part Number
PROMVI46DFNT
Manufacturer Part Number
MVI46-DFNT
Manufacturer
Prosoft Technology
$5,989.00Â /Â E
Each
Each
- Features
- Specifications
- Resources
- The MVI46-DFNT module is a single slot solution that provides a powerful connection between Rockwell Automation's SLC processor and EtherNet/IP (DF1 for Ethernet) network applications.
- The module can send read or write commands to remote devices on the EtherNet/IP network. The MVI46-DFNT also has 20 servers that allow the module to receive commands from remote devices. The MVI46-DFNT Pass-Through server allows the user to edit and transfer the SLC ladder logic using an Ethernet connection. Up to 100 commands can be configured by the user.
- List of Rockwell Automation material that support EPIC:
- PLC5/E rev C/N, D/E, E/D
- SLC5/05 series A, OS503 frn4
- 1785-ENET Series A, rev D
- Interchange V6.2
- MicroLogix 1100/1400/ANY via 1761-NET-ENI
- CompactLogix 1768-L43/L45 via 1768-ENBT
- CompactLogix 1769-L32E/L35E/ANY via 1761-NET-ENI
- RSLinx Gateway V1.7+
- ControlLogix 1756-ENET/ENBT/EN2T
- Single Slot - 1746 backplane compatible (Local or extended I/O rack only. Remote rack not supported)
- The module is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module using M0/M1 files
- Ladder Logic is used for data transfer between module and processor. Sample ladder file included
- Configuration data obtained from configuration text file downloaded to module. Sample configuration file included
- Single Slot - 1746 backplane compatible (Local or extended I/O rack only. Remote rack not supported)
- The module is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module using M0/M1 files
- Ladder Logic is used for data transfer between module and processor. Sample ladder file included
- Configuration data obtained from configuration text file downloaded to module. Sample configuration file included
- Rockwell Automation equipment that supports EPIC:
- PLC5/E rev C/N, D/E, E/D
- SLC5/05 series A, OS503 frn4
- 1785-ENET Series A, rev D
- Interchange V6.2
- MicroLogix 1100/1400/ANY via 1761-NET-ENI
- CompactLogix 1768-L43/L45 via 1768-ENBT
- CompactLogix 1769-L32E/L35E/ANY
- CompactLogix L23E
- RSLinx Gateway V1.7+
- ControlLogix 1756-ENET/ENBT/EN2T/EN2TR
- Rockwell Automation 5/02/03/04 processors with DH-485 or DH+ network connections to co-exist with EtherNet/IP network
- SLC 5/05 in-chassis EtherNet/IP bridge to optimize data throughput while communicating with MMI or SCADA and other control platforms without losing valuable process control bandwidth
- Support of up to 4000 SLC registers user data files
- User-definable module memory usage
- 10/100 MB Ethernet compatible interface
- Functions as a server or a client
- Configurable parameters for the client include:
- A minimum response delay of 0 to 65535 mSec
- A response timeout of 1 to 65535 mSec
- A retry count of 0 to 20
- Status data available in ladder logic
- Support for SLC processor programming over Ethernet using a TCP/IP service and a serial port on the module connected to channel 0 of the processor. The module's third port emulates Channel 0 of the processor to pass through messages from the port to the processor
- Supports EtherNet/IP explicit, connected, and unconnected class messaging
- Twenty independent server connections permit remote clients to interact with all data contained in the module
- Data can be derived from other clients on the network, through the client on the module, or from the SLC processor
- Actively issues connected, explicit messages to other nodes on the network
- Supports 100 user-defined commands from a single client
- Allows command control from ladder logic
- Pass-through services
- Permits remote programming of the SLC processor on the Ethernet network via a pass-through
- TCP/IP service and a serial communication port (pass-through port) on the module
- A PC with RSLogix 500, RSLinx, and a TCP/IP service on the network can remotely program the SLC
- The third port on the module can emulate the Channel 0 port on the SLC. This allows a DF1 master device attached to the emulated (Channel 0) port to monitor and control data in the SLC.
Specifications
Protocol | :Â Â | Ethernet/IP |
Mounting Method | :Â Â | Chassis |
Platform | :Â Â | SLC |
- The MVI46-DFNT module is a single slot solution that provides a powerful connection between Rockwell Automation's SLC processor and EtherNet/IP (DF1 for Ethernet) network applications.
- The module can send read or write commands to remote devices on the EtherNet/IP network. The MVI46-DFNT also has 20 servers that allow the module to receive commands from remote devices. The MVI46-DFNT Pass-Through server allows the user to edit and transfer the SLC ladder logic using an Ethernet connection. Up to 100 commands can be configured by the user.
- List of Rockwell Automation material that support EPIC:
- PLC5/E rev C/N, D/E, E/D
- SLC5/05 series A, OS503 frn4
- 1785-ENET Series A, rev D
- Interchange V6.2
- MicroLogix 1100/1400/ANY via 1761-NET-ENI
- CompactLogix 1768-L43/L45 via 1768-ENBT
- CompactLogix 1769-L32E/L35E/ANY via 1761-NET-ENI
- RSLinx Gateway V1.7+
- ControlLogix 1756-ENET/ENBT/EN2T
- Single Slot - 1746 backplane compatible (Local or extended I/O rack only. Remote rack not supported)
- The module is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module using M0/M1 files
- Ladder Logic is used for data transfer between module and processor. Sample ladder file included
- Configuration data obtained from configuration text file downloaded to module. Sample configuration file included
- Single Slot - 1746 backplane compatible (Local or extended I/O rack only. Remote rack not supported)
- The module is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module using M0/M1 files
- Ladder Logic is used for data transfer between module and processor. Sample ladder file included
- Configuration data obtained from configuration text file downloaded to module. Sample configuration file included
- Rockwell Automation equipment that supports EPIC:
- PLC5/E rev C/N, D/E, E/D
- SLC5/05 series A, OS503 frn4
- 1785-ENET Series A, rev D
- Interchange V6.2
- MicroLogix 1100/1400/ANY via 1761-NET-ENI
- CompactLogix 1768-L43/L45 via 1768-ENBT
- CompactLogix 1769-L32E/L35E/ANY
- CompactLogix L23E
- RSLinx Gateway V1.7+
- ControlLogix 1756-ENET/ENBT/EN2T/EN2TR
- Rockwell Automation 5/02/03/04 processors with DH-485 or DH+ network connections to co-exist with EtherNet/IP network
- SLC 5/05 in-chassis EtherNet/IP bridge to optimize data throughput while communicating with MMI or SCADA and other control platforms without losing valuable process control bandwidth
- Support of up to 4000 SLC registers user data files
- User-definable module memory usage
- 10/100 MB Ethernet compatible interface
- Functions as a server or a client
- Configurable parameters for the client include:
- A minimum response delay of 0 to 65535 mSec
- A response timeout of 1 to 65535 mSec
- A retry count of 0 to 20
- Status data available in ladder logic
- Support for SLC processor programming over Ethernet using a TCP/IP service and a serial port on the module connected to channel 0 of the processor. The module's third port emulates Channel 0 of the processor to pass through messages from the port to the processor
- Supports EtherNet/IP explicit, connected, and unconnected class messaging
- Twenty independent server connections permit remote clients to interact with all data contained in the module
- Data can be derived from other clients on the network, through the client on the module, or from the SLC processor
- Actively issues connected, explicit messages to other nodes on the network
- Supports 100 user-defined commands from a single client
- Allows command control from ladder logic
- Pass-through services
- Permits remote programming of the SLC processor on the Ethernet network via a pass-through
- TCP/IP service and a serial communication port (pass-through port) on the module
- A PC with RSLogix 500, RSLinx, and a TCP/IP service on the network can remotely program the SLC
- The third port on the module can emulate the Channel 0 port on the SLC. This allows a DF1 master device attached to the emulated (Channel 0) port to monitor and control data in the SLC.
Specifications
Protocol :Â Â Ethernet/IP Mounting Method :Â Â Chassis Platform :Â Â SLC - Certifications
CE Mark
Russian GOST-R
Korean KC Registration
UL/cUL; Class 1, Div 2
UL/cUL; Class 1, Div 2 (Canada)
Downloads
MVI46-DFNT Datasheet
MVI46-DFNT User Manual
MVI46-DFNT Sample Ladder
MVI46-DFNT Configuration File
WATTCP Configuration