HESCO
EtherNet/IP Client/Server Network Interface Module for SLC

EtherNet/IP Client/Server Network Interface Module for SLC

MFG #MVI46-DFNT

$5,989.00 / E
Each
Product Description:
The EtherNet/IP Client/Server Network Interface Module allows SLC processors to interface with EtherNet/IP protocol (Explicit Messaging) compatible devices and hosts. The SLC 5/05 with the MVI46-DFNT module provides a second EtherNet/IP port to a separate subnet for communicating with a HMI or SCADA host. For other SLC processors the module provides a serial pass-thru channel 0 service for remote Ethernet programming and troubleshooting.
HESCO Part Number
PROMVI46DFNT
Manufacturer Part Number
MVI46-DFNT
Manufacturer
Prosoft Technology

EtherNet/IP Client/Server Network Interface Module for SLC

MFG #MVI46-DFNT

Product Description:
The EtherNet/IP Client/Server Network Interface Module allows SLC processors to interface with EtherNet/IP protocol (Explicit Messaging) compatible devices and hosts. The SLC 5/05 with the MVI46-DFNT module provides a second EtherNet/IP port to a separate subnet for communicating with a HMI or SCADA host. For other SLC processors the module provides a serial pass-thru channel 0 service for remote Ethernet programming and troubleshooting.
HESCO Part Number
PROMVI46DFNT
Manufacturer Part Number
MVI46-DFNT
Manufacturer
Prosoft Technology
$5,989.00 / E
Each
  • The MVI46-DFNT module is a single slot solution that provides a powerful connection between Rockwell Automation's SLC processor and EtherNet/IP (DF1 for Ethernet) network applications.
  • The module can send read or write commands to remote devices on the EtherNet/IP network. The MVI46-DFNT also has 20 servers that allow the module to receive commands from remote devices. The MVI46-DFNT Pass-Through server allows the user to edit and transfer the SLC ladder logic using an Ethernet connection. Up to 100 commands can be configured by the user.
  • List of Rockwell Automation material that support EPIC:
  • PLC5/E rev C/N, D/E, E/D
  • SLC5/05 series A, OS503 frn4
  • 1785-ENET Series A, rev D
  • Interchange V6.2
  • MicroLogix 1100/1400/ANY via 1761-NET-ENI
  • CompactLogix 1768-L43/L45 via 1768-ENBT
  • CompactLogix 1769-L32E/L35E/ANY via 1761-NET-ENI
  • RSLinx Gateway V1.7+
  • ControlLogix 1756-ENET/ENBT/EN2T
  • Single Slot - 1746 backplane compatible (Local or extended I/O rack only. Remote rack not supported)
  • The module is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module using M0/M1 files
  • Ladder Logic is used for data transfer between module and processor. Sample ladder file included
  • Configuration data obtained from configuration text file downloaded to module. Sample configuration file included
  • Single Slot - 1746 backplane compatible (Local or extended I/O rack only. Remote rack not supported)
  • The module is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module using M0/M1 files
  • Ladder Logic is used for data transfer between module and processor. Sample ladder file included
  • Configuration data obtained from configuration text file downloaded to module. Sample configuration file included
  • Rockwell Automation equipment that supports EPIC:
  • PLC5/E rev C/N, D/E, E/D
  • SLC5/05 series A, OS503 frn4
  • 1785-ENET Series A, rev D
  • Interchange V6.2
  • MicroLogix 1100/1400/ANY via 1761-NET-ENI
  • CompactLogix 1768-L43/L45 via 1768-ENBT
  • CompactLogix 1769-L32E/L35E/ANY
  • CompactLogix L23E
  • RSLinx Gateway V1.7+
  • ControlLogix 1756-ENET/ENBT/EN2T/EN2TR
  • Rockwell Automation 5/02/03/04 processors with DH-485 or DH+ network connections to co-exist with EtherNet/IP network
  • SLC 5/05 in-chassis EtherNet/IP bridge to optimize data throughput while communicating with MMI or SCADA and other control platforms without losing valuable process control bandwidth
  • Support of up to 4000 SLC registers user data files
  • User-definable module memory usage
  • 10/100 MB Ethernet compatible interface
  • Functions as a server or a client
  • Configurable parameters for the client include:
  • A minimum response delay of 0 to 65535 mSec
  • A response timeout of 1 to 65535 mSec
  • A retry count of 0 to 20
  • Status data available in ladder logic
  • Support for SLC processor programming over Ethernet using a TCP/IP service and a serial port on the module connected to channel 0 of the processor. The module's third port emulates Channel 0 of the processor to pass through messages from the port to the processor
  • Supports EtherNet/IP explicit, connected, and unconnected class messaging
  • Twenty independent server connections permit remote clients to interact with all data contained in the module
  • Data can be derived from other clients on the network, through the client on the module, or from the SLC processor
  • Actively issues connected, explicit messages to other nodes on the network
  • Supports 100 user-defined commands from a single client
  • Allows command control from ladder logic
  • Pass-through services
  • Permits remote programming of the SLC processor on the Ethernet network via a pass-through
  • TCP/IP service and a serial communication port (pass-through port) on the module
  • A PC with RSLogix 500, RSLinx, and a TCP/IP service on the network can remotely program the SLC
  • The third port on the module can emulate the Channel 0 port on the SLC. This allows a DF1 master device attached to the emulated (Channel 0) port to monitor and control data in the SLC.