SolaHD™ International Series Control Transformers - PN E250TF
MFG #E250TF
$491.49 / E
Each
Each
Product Description:
Electromagnetic control components demand inrush currents up to 10 times the transformer's nominal rating without sacrificing secondary voltage stability beyond practical limits. International Series transformers fully comply with IEC and NEMA standards and are available with IEC touchproof covers (IP20).
HESCO Part Number
HEDE250TF
Manufacturer Part Number
E250TF
Manufacturer
Sola/Hevi-Duty
SolaHD™ International Series Control Transformers - PN E250TF
MFG #E250TF
$491.49 / E
Each
Each
Product Description:
Electromagnetic control components demand inrush currents up to 10 times the transformer's nominal rating without sacrificing secondary voltage stability beyond practical limits. International Series transformers fully comply with IEC and NEMA standards and are available with IEC touchproof covers (IP20).
HESCO Part Number
HEDE250TF
Manufacturer Part Number
E250TF
Manufacturer
Sola/Hevi-Duty
SolaHD™ International Series Control Transformers - PN E250TF
MFG #E250TF
Product Description:
Electromagnetic control components demand inrush currents up to 10 times the transformer's nominal rating without sacrificing secondary voltage stability beyond practical limits. International Series transformers fully comply with IEC and NEMA standards and are available with IEC touchproof covers (IP20).
HESCO Part Number
HEDE250TF
Manufacturer Part Number
E250TF
Manufacturer
Sola/Hevi-Duty
$491.49 / E
Each
Each
- Features
- Specifications
- Resources
- cULus, CE, RoHS
- Epoxy encapsulated for cooler operation
- Interleaved copper windings to reduce impedance
- 50/60 Hz +55°C Rise
- +105°C insulation system for harsh, heavy duty applications
- Exceeds IEC, NEMA, ANSI, NMTBA, JIC and automotive standards
Specifications
Group 1 | : | 208/240/415 Volt Primary, 120/24 Secondary, 50/60 Hz; 200/230/400 Volt Primary, 115/23 Secondary, 50/60 Hz; 50, 100, 150, 250, 500 Continuous VA |
Group 2 | : | 208/240/415 Volt Primary, 24 Volt Secondary, 50/60 Hz; 277/480 Volt Primary, 24 Volt Secondary, 60 Hz; 200/230/400 Volt Primary, 24 Volt Secondary, 50/60 Hz; 220/380 Volt Primary, 23 Volt Secondary, 50/60 Hz50, 100, 150, 250, 500 Continuous VA |
Group 3 | : | 208/240/415/480/600 Volt Primary, 120 Volt Secondary, 50/60 Hz; 200/230/400/460/575 Volt Primary, 115 Volt Secondary, 50/60 Hz220/277/380 Volt Primary, 110 Volt Secondary, 50/60 Hz50, 100, 150, 250, 500, 750 Continuous VA |
Group 4 | : | 240/415/480 Volt Primary, 120/240 Volt Secondary, 50/60 Hz; 230/400/460 Volt Primary, 115/230 Volt Secondary, 50/60 Hz; 220/380/440 Volt Primary, 110/220 Volt Secondary, 50/60 Hz; 50, 100, 150, 250, 500, 750 Continuous VA |
Hertz | : | 50/60 Hz |
KVA Rating | : | 50, 100, 150, 250, 500, 750 |
Primary Voltage | : | Options available between 220 and 575 |
Secondary Voltage | : | Options available between 95 and 240 |
Temperature Rise | : | +55°C |
Windings | : | Copper |
Mounting | : | Mounting Feet |
- cULus, CE, RoHS
- Epoxy encapsulated for cooler operation
- Interleaved copper windings to reduce impedance
- 50/60 Hz +55°C Rise
- +105°C insulation system for harsh, heavy duty applications
- Exceeds IEC, NEMA, ANSI, NMTBA, JIC and automotive standards
Specifications
Group 1 : 208/240/415 Volt Primary, 120/24 Secondary, 50/60 Hz; 200/230/400 Volt Primary, 115/23 Secondary, 50/60 Hz; 50, 100, 150, 250, 500 Continuous VA Group 2 : 208/240/415 Volt Primary, 24 Volt Secondary, 50/60 Hz; 277/480 Volt Primary, 24 Volt Secondary, 60 Hz; 200/230/400 Volt Primary, 24 Volt Secondary, 50/60 Hz; 220/380 Volt Primary, 23 Volt Secondary, 50/60 Hz50, 100, 150, 250, 500 Continuous VA Group 3 : 208/240/415/480/600 Volt Primary, 120 Volt Secondary, 50/60 Hz; 200/230/400/460/575 Volt Primary, 115 Volt Secondary, 50/60 Hz220/277/380 Volt Primary, 110 Volt Secondary, 50/60 Hz50, 100, 150, 250, 500, 750 Continuous VA Group 4 : 240/415/480 Volt Primary, 120/240 Volt Secondary, 50/60 Hz; 230/400/460 Volt Primary, 115/230 Volt Secondary, 50/60 Hz; 220/380/440 Volt Primary, 110/220 Volt Secondary, 50/60 Hz; 50, 100, 150, 250, 500, 750 Continuous VA Hertz : 50/60 Hz KVA Rating : 50, 100, 150, 250, 500, 750 Primary Voltage : Options available between 220 and 575 Secondary Voltage : Options available between 95 and 240 Temperature Rise : +55°C Windings : Copper Mounting : Mounting Feet - Downloads
Spec Sheet
BrochuresBrochure: Oil and Gas | SolaHD
CatalogsCatalog: International Series Control Transformers | SolaHD
Manuals & GuidesInstruction Manual: International Industrial Control Transformers 50-750 VA | SolaHD